⚡ Descuentos en cursos en video - Lleva tu aprendizaje técnico al siguiente nivel y aprovecha precios especiales antes de que termine la oferta. 🔥 Aprovechar oferta ahora 🔥
Refrigerators

Fridge Whirlpool ARF 434 No Engine Arrcanca

nacho197822
hace 5 años
hace 5 años
Hello, good afternoon dear, I bother you to ask about this refrigerator. It was repaired halfway by a colleague since the client calls me to change the engine that was the last thing he needed to change (he changed a forger, filter and you pray more things between them thermostat) Then I change the engine, I start it and it works but it doesn't cut. When reviewing it I see that it does not work and tells me that they had changed it for a different one. I try that one but when I connect it I don't start on that opportunity. After searching I could find the original and placed it and the refrigerator does not start. I check the electrical connection according to the diagram and see that it was fine. I test the engine live and it works perfectly the issue is that with the thermostat it does not start. I really don't know what the fault may be. Now change the timer and notice that when you start the thermostat, what it does is start the timer, you can hear it running but the engine is not at all. I hope suggestions from now thank you very much attached some images. 20180303_202333.jpg [686.08kb] 20180303_205039.jpg [474.64kb] 20180310_143217.jpg[449.50kb]20180310_143244.jpg[469.59kb]20180 310_143201.jpg [533.90kb] 20180310_131204.jpg [468.42kb] Claudio.
gustavo gabrieltecnico
hace 5 años
hace 5 años
hello nacho, if the motor compressor starts directly then you have problems with the thermostat, turn it on and run it, if it starts, change it, check that the timer is freezing, greetings.
nacho197822
hace 5 años

Hi, how are you? Thank you for your input. As for the thermostat he said it is new, that catches my attention and is the same as it had original (although it cost me to get it for being a refrigerator of 20 years approx).
The timer replaced it with another one since the original one did not get it but I am not sure the connection in the images are the connections that it has.
I find it striking that suddenly I stop starting and there is no case check all the wiring and the circuit but I can not make it work, the fuses are all well ...

Responder
gustavo gabrieltecnico
hace 5 años

You did the test as I told you!

Responder
nacho197822
hace 5 años

Dear thank you very much for your input, finally the problem was a connection error in the timer I had inverted the defrosting cable with the compressor. Apart from that it lacked a little gas but it really worked out of ten, I really appreciate your contribution every day you learn something new. Regards.

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.25
(8)

Reparación de Placa Main TV LED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 40 USD
$ 20 USD
4.6
(10)

Curso Localización de Fallas en Refrigeración en Heladeras/Neveras On/Off

Yamil Alarcón
$ 29 USD
$ 12 USD
4.64
(45)

Curso Tecnología Inverter - Fabricación de probadores y herramientas

Yamil Alarcón
$ 240 USD
$ 40 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis