excellent friend thank you very much I think that is my problem, because as I did not find the original relay I adapted a universal one, can that be true what you say? that because of this relay as it is not the original one, it is not able to open and sticks, I am afraid to buy everything again and it will burn again and look bad again, but I will try it maybe that is the problem, tomorrow I will try and I'll give you a hand up and the best solution thank you very much hopefully that is it.
Hi Faustino, he did use a universal relay of the 4-terminal ones, surely that is what happens to him, he must open the new universal relay and with a silvery, triangular, file of the little ones, you can cut carefully not to do it for the same center of the contacts because it can damage the welding point of the contacts with the PTC tablet, when trying to make the division, carefully observe the images where it appears as the radiography of the relay, so that it takes into account well what is the terminal to divide and exactly where, to achieve a good adaptation. of relay
Hi Faustino, now checking the internet, I found a page of the free market of Venezuela where he says that this compressor model is 1/4 HP
https://articulo.mercadolibre.com.ve/MLV-543209199-compresor-para-nevera-de-14-cinco-tubos-marca-kulthorn-c-bz-_JM#position=1&type=item&tracking_id=194702e1-58c7- 435d-beb8-f07a7dcb3a65
Excellent friend, thank you very much, that diagram that you sent me served me, if it was that, I was connecting the capacitor badly, thanks to that diagram I realized since it is the same relay that I am mounting, and the starting capacitor connected it as if I was a marching capacitor, and that is why it exploded, thank you very much. Is the best solution
Hello Faustino, I am very pleased to be able to help you, as long as it is within our reach we will continue to cooperate. Good luck in the future and thanks for the communication. S @ lu2 friovega63.