Haier 19-foot refrigerator explodes the capacitor, what can it be?

faustino
hace 6 años
hace 6 años
good night how are you friends? I have a problem with a 19-foot haier refrigerator, I changed the starter kit because it was damaged, I worked well for 15 days, the compressor made a strange sound and turned it off I went to check it again and measured the starter relay and it was again damaged, I replaced it with another relay, I turned on the unit and started the compressor well and in 2 minutes the 60uf capacitor explodes, I buy the capacitor again with the same 60uf, and in the same way it explodes it again, I don't know what the problem, as many of you know I am new to this, and I would like you to solve the problem, I would greatly appreciate it, start the direct compressor and start it on 5 minutes and it gets very hot I don't know if this will be normal, no I know how much amperage this compressor works because it does not bring the information on the label, what do you think it might be? Why is the capacitor exploded? Below are the photos of the capacitor and the label that the compressor brings.
friovega63
friovega63
11.849
hace 6 años
hace 6 años
Hello Faustino, right now I could not tell you what the capacity of your compressor is, because it would be necessary to search on the internet, for the model that says on your chapilla or informative label. The compressor brand would be (KULTHORN) and the model would be (C-BZN176L2Z) with that information, its capacity and consumption may be found. Obviously, or the compressor is damaged, or maybe it bursts the capacitors, because the relay you are using does not have the corresponding divisions in its contacts so that a starting capacitor is connected to it like the one you are trying to connect. If the order of the connection in the compressor terminals, common bone, running and starting, is well located, you can test the compressor directly, using the thermal protection of the same compressor, to know if the latter is really damaged or not, if the protection does not trip after starting the compressor for a reasonable time, it would mean that it is not damaged and what happens, is that it does not connect the capacitor well, constantly sticking the same, bone permanently as a way of Electrolytic capacitor, without obviously being it and that is why it heats up to bursting, or the repeat relay, which you are using, is not designed for the use of starting capacitor and must in that case adapt the relay itself for that connection, making it the corresponding internal division, so that in a row that the compressor can start, the connection to the compressor start and the capacitor itself is opened, or it should get a n relay with the appropriate design so that this type of capacitor can run smoothly with the relay itself used and the compressor of your equipment. If you still have doubts, please comment. Luck. S @ lu2 friovega63.
faustino
hace 6 años

excellent friend thank you very much I think that is my problem, because as I did not find the original relay I adapted a universal one, can that be true what you say? that because of this relay as it is not the original one, it is not able to open and sticks, I am afraid to buy everything again and it will burn again and look bad again, but I will try it maybe that is the problem, tomorrow I will try and I'll give you a hand up and the best solution thank you very much hopefully that is it.

Responder
friovega63
friovega63
11.849
hace 6 años

Hi Faustino, he did use a universal relay of the 4-terminal ones, surely that is what happens to him, he must open the new universal relay and with a silvery, triangular, file of the little ones, you can cut carefully not to do it for the same center of the contacts because it can damage the welding point of the contacts with the PTC tablet, when trying to make the division, carefully observe the images where it appears as the radiography of the relay, so that it takes into account well what is the terminal to divide and exactly where, to achieve a good adaptation. of relay

Responder
friovega63
friovega63
11.849
hace 6 años

Hi Faustino, now checking the internet, I found a page of the free market of Venezuela where he says that this compressor model is 1/4 HP
https://articulo.mercadolibre.com.ve/MLV-543209199-compresor-para-nevera-de-14-cinco-tubos-marca-kulthorn-c-bz-_JM#position=1&type=item&tracking_id=194702e1-58c7- 435d-beb8-f07a7dcb3a65

Responder
faustino
hace 6 años

Excellent friend, thank you very much, that diagram that you sent me served me, if it was that, I was connecting the capacitor badly, thanks to that diagram I realized since it is the same relay that I am mounting, and the starting capacitor connected it as if I was a marching capacitor, and that is why it exploded, thank you very much. Is the best solution

Responder
friovega63
friovega63
11.849
hace 6 años

Hello Faustino, I am very pleased to be able to help you, as long as it is within our reach we will continue to cooperate. Good luck in the future and thanks for the communication. S @ lu2 friovega63.

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.84
(25)

Curso Práctico de Reparación y Bobinado de Motores Eléctricos

Héctor Castiñeira
$ 60 USD
$ 20 USD
4.94
(16)

Curso Refrigeración Comercial Aplicado a Diagnóstico y Reparación

Ing. Georga Melgarejo
$ 40 USD
$ 13 USD
4.71
(7)

Curso TV OLED y QLED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 29 USD
$ 10 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis