Hello, from what I see in the table, it is for a 5000 omhs tester.
You need another table for those sensors.
Comment
If you look for them on the web, at 20 degrees the 2.7 k has a resistive value of 3.35 k.
Let it defrost for 48Hs and let the air ducts and the water drain be clean.
Yes now!! thanks,. ,, Well, I tell you, I put two 2.4k thermistors ... which at 21 degrees are giving me 2.80 ohms ,, Almost within the range ... I'll see how it turns out ... and if it works well ... I pass the data of where to buy them at $ 22 each .. with a pen they make the protector, with the plastic gun they seal it on both sides, and voila ..
Yes now!! thanks,. ,, Well, I tell you, I put two 2.4k thermistors ... which at 21 degrees are giving me 2.80 ohms ,, Almost within the range ... I'll see how it turns out ... and if it works well ... I pass the data of where to buy them at $ 22 each .. with a pen they make the protector, with the plastic gun they seal it on both sides, and voila ..