Hello good night, could someone explain the diagram to me?

Alejandrino
hace 6 años
hace 6 años
I have a panavox model nf30w refrigerator the diagram I can not get it has a sonxie 807 2g5 timmer
luiscataño
luiscataño
1.045
hace 6 años
hace 6 años
If you tell me about the electrical components that said refrigerator has, I can make you one and send it to you this way
sergiosilvestre
hace 6 años
hace 6 años
HELLO Alejandrino. Here I attached the diagram of the refrigerator you have. I hope it helps you. Of course I hope I have helped you or even contributed to the solution of your problem. Regards
Alejandrino
hace 6 años

Thank you I wanted to upload the photo but I could not the subject I have it when the current enters the bimetal if it is open as jace to reach the timmer to work or layers that it is bung before and in the photo shows that it is before it goes to the timmer another thing I saw is if I was bung with the neutral entities for the 1 timmer coil if the bimetal is closed it would not go towards the resistance and not towards the timmer's motor I have those concerns or someone who can explain it to me thank you very much

Responder
Fermin 007
Fermin 007
57.307
hace 6 años
hace 6 años
Alejandrino, what is happening with this refrigerator? does not defrost automatically? You have already checked the bimetal, it is checked by freezing it and already frozen it should mark you CONTINUITY, look at this, disconnect the fan and then with the cover removed from the freezer, let the whole coil be covered with frost, all complete, since this full, you will turn the timer, of its short shank with a flat screwdriver little by little clockwise, you will hear a click immediately cut the compressor and start heating the resistance, if not, possibly the thermo -fuse is open or the bimetal is not active, or the resistance is already damaged or the internal platinum of the timer that actuate the resistance is damaged, this possibility is very remote, check the 4 possibilities, thermo - fuse, bimetal or resistance and finally the timer, of course it is in the case that you do not heat the resistance with the test that indicates you, greetings
Alejandrino
hace 6 años

Hello fermin the refrigerator had broken the bimetal but what I want to know is how the defrosting part works in the diagram that the wild friend went up so I see in the diagram a white wire enters the bimetal a blue wire leaks one for the resistance and one for the timmer motor now that is the doubt that I have how it will enter through the white cable that comes from the current to the bimetal and well if the bimetal is closed and changes to pin two the resistance will turn but if the bimetal where the current passes to the timmer motor

Responder
Fermin 007
Fermin 007
57.307
hace 6 años

Ahh yes of course, if the bimetal is damaged, that is, it always remains open, the timer motor will not turn, therefore, it will not start the automatic defrosting process and will fill with ice above, greetings

Responder
gustavo gabrieltecnico
hace 6 años

Hello friend, to provide another piece of information, between the bimetal and the resistance there must be a thermal fuse, which you do not mention, if you do not have it put a 72 degree, greetings.

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.25
(8)

Reparación de Placa Main TV LED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 40 USD
$ 20 USD
4.73
(22)

Curso Reparación de Fuentes Conmutadas de PC y Equipos Electrónicos

Maximiliano Resch
$ 40 USD
$ 20 USD
4.87
(15)

Curso Diseño de Amplificadores de Máxima Fidelidad

Maximiliano Resch
$ 29 USD
$ 13 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis