Hi Fermin 007, thanks for replying. Is there any possible measurement for temperature control and know if it works correctly? Regards
The temperature control sensor must measure at 5kohms at 25 ° C and must increase the ohms when the sensor cools, if for some reason you see that the ohms do not increase or mark badly, because the sensor is wrong, but on the contrary , you see that it marks 5 kohms at 25 ° C and the ohms are increasing because it is good, usually it is the potentiometer that is damaged, check if the electronic card brings potentiometer, greetings