Good, best regards to all. I have a refrigerator Refrigerator GE model Smart Fresh, No Frost 19 ″ white .. 523 Lts. capacity. 2 doors 4 shelves 2 tempered glass shelves. 1 large drawer for cold meats. Humidity controls. Bottle separator. Climate class ST. Ice Factory Light inside. Adjustable legs and wheels. Energy efficiency: Class B. Dimensions: Height 187.8 cm x width 74.33 cm x depth 73.73 cm. Weight: 83 Kg First I mention that the fridge has a voltage protector for EXCELINE refrigerators, I don't know if it is important to mention it. On the afternoon of today there was first a downturn that caused my computer where I worked to shut down and immediately turn on and minutes later the light went out completely for 2 hours. When the light came back I plugged in the voltage protector waiting for the refrigerator to turn on normally, the internal lights turned on but after a while I noticed that when I opened the fridge it didn't cool at all, it felt warm and the sound of the motor was not heard when it was running . As I fear that the light goes out in the early morning choose to unplug it. Before calling the technician I want to know if there is anything I can do and / or check: - ( Could you please guide me. Greetings and thanks
Mimol92
Mimol92
8.033
hace 6 años
hace 6 años
Good morning, check if the freezer fan turns on, many of them work with the door switch, press that switch and check if the inside fan turns on, in case you don't turn on the fan, most likely it has been damaged the thermostat or the timer has stuck in the defrost cycle (if the refrigerator is analog), if it is digital, the temperature sensors or the electronic board should be checked; If you notice that the fan turns on, then it is most likely that the problem is located in the compressor, but for this you need an ammeter clamp to check its electrical consumption, it may not turn on because the thermal protector of the compressor remained open with the downer of light, or the compressor relay may have been damaged, also in these cases the most serious thing is that the compressor has landed (grounded) or mechanically glued If the compressor notes that it turns on normally, then the working pressure should be checked With a pressure gauge, you may have a refrigerant (gas) leak, partial obstruction in the dehydrator filter and / or capillary tube, or the compressor has lost performance, that is, it turns on but does not compress (does not pump).
Karin
Karin
2
hace 6 años

Thank you for your prompt response, I am sorry I could not answer you, I also damaged the router:

Responder
Fermin 007
Fermin 007
57.307
hace 6 años
hace 6 años
Karin you have to look for the electronic card and check it, possibly if you bring a transformer the primary coil is damaged, greetings
Karin
Karin
2
hace 6 años

Hi thanksssss that will do!

Responder
Fermin 007
Fermin 007
57.307
hace 6 años

LIKE THAT ARAS? IF YOU ALREADY GIVEN THE SOLUTION, to the colleague, are you supposed to have solved or are you just going to check? I do not understand, well, greetings

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.25
(8)

Reparación de Placa Main TV LED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 40 USD
$ 20 USD
4.71
(7)

Curso TV OLED y QLED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 29 USD
$ 10 USD
4.64
(11)

Curso Electrónica para Reparación de Placas

Santiago Cediel
$ 29 USD
$ 11 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis