freezer gafa m210 does not cool

Matias Alejandro
hace 6 años
hace 6 años
Good morning. I tell you that suddenly the freezer stopped working, although it turns on and the motocompressor also I do not see that I cooled. What if I am hearing that compressor makes a little more noise than before. I get the feeling that I run out of refrigerant. You say I should weld the service valve? How much are the psi you have to have? Or what should I try with the compressor if it is working properly?
Fermin 007
Fermin 007
57.307
hace 6 años
hace 6 años
Matias Weld the service valve to check its pressure? I understood that, sorry if I'm wrong, but if it is to see if it has gas or not, that is not done, because when placing the service valve by logic the refrigerant will come out, a pinch valve is placed and so, if you can see What is the pressure on the low side, I am one of those who do not like to waste time, well, short where the filter is and so I see if it has gas or not, if I see a little gas spark, then that team It brings a leak somewhere in the pipe or pipe, but if enough gas comes out, it is logical that the filter was clogged or in a given case, the compressor lost performance, in short, and after the compressor was disengaged, the test of compression or right there cover with a finger the output of the condenser and if it throws my finger because this means that the compressor still has very good compression, if you want a more precise data because a service valve is put on the high tube and the gauges are placed, etc, etc, but for what you say, it seems that that team lost the refrigerant due to leakage, regards
Matias Alejandro
hace 6 años

Thanks for the information but then you say that the compressor to stay if refrigerant, seems to make more noise. I will try it.

Responder
Fermin 007
Fermin 007
57.307
hace 6 años

Matias
Of course, when running out of refrigerant it releases and there is no pressure, it makes more noise and must have less amperage (load measurement) if you have the tests, working the equipment, cut the tube where the filter goes and see if Gas comes out, if a spark or pure air comes out, because that's it, that team lost the gas due to leakage, now you cut the appendix where the service valve goes and thus working the refrigerator, cover with a finger and it must feel that you throws, of course after a few seconds and releasing or releasing the tube will press the air with pressure, this you repeat for several

Responder
Fermin 007
Fermin 007
57.307
hace 6 años

I finished the space hehe told you, repeat it several times, if you notice oil or moisture, you will have to look for the leak, in the case that the pipe is completely hidden, you better not mess with those "chafa" equipment you would have to discover the pipe and then change all the copper pipe, in short, a very hard work and worst of all, you do not earn much hehe, greetings and luck.

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.93
(14)

Curso Reparación de Equipos de Audio de Alta Fidelidad

Maximiliano Resch
$ 60 USD
$ 20 USD
4.25
(8)

Reparación de Placa Main TV LED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 40 USD
$ 20 USD
4.64
(45)

Curso Tecnología Inverter - Fabricación de probadores y herramientas

Yamil Alarcón
$ 240 USD
$ 40 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis