⚡ Descuentos en cursos en video - Lleva tu aprendizaje técnico al siguiente nivel y aprovecha precios especiales antes de que termine la oferta. 🔥 Aprovechar oferta ahora 🔥
Refrigerators

psi pressure with gas r12

mrp2015
mrp2015
47
hace 6 años
hace 6 años
Good evening people, I am in need of help, I tell you that I work in a frizzer, change engine, filter, vacuum, gas load, it turns out that when the frezzer reaches a temperature of -24º in the pressure gauge it skips to me that it is working in vacuum, the gas is mo49, is that pressure ok? Thank you
Romer
Romer
295
hace 6 años
hace 6 años
The original r12 we know is a pure gas and is charged in the gas phase for home refrigerators. The substitute blends are mixtures of 2 or 3 gases and are therefore charged in liquid phase. for such reasons the behaviors in operation are different and the performance too. R12, R22, R134 are pure, they can be increased or removed without altering their composition. The blends do not, to load it is in liquid phase as already said and to remove it you have to turn off the machine and wait for the pressures to level. otherwise they decompensate. The mixed gases have different densities, when gas is removed in the gas phase they come in different percentages. In any case I would recommend you load it with R600 and you will have a result similar to r12. and works with it. oil than 12
lusangor
lusangor
56.366
hace 6 años
hace 6 años
Hello You can raise the pressure a little, up to 2 psi and check its behavior. You can increase the pressure while the return or lower tube does not freeze Regards
mrp2015
mrp2015
47
hace 6 años

Hello good day thanks for answering, I did the test but the return pipe freezes, this frezzer has an engine of 1/6 of the old models that bring down an oil cooler, and then goes to the condenser, this new engine of 1 / 6 does not bring the same, what I am going to do is cancel that cooler and connect directly to the condenser, to see what it does

Responder
lusangor
lusangor
56.366
hace 6 años

if the return freezes, it is passed refrigerant. Without canceling anything, so that you do not lose the refrigerant, try to remove the refrigerant, until the return thaws and so it is left with the load that must work

Responder
lusangor
lusangor
56.366
hace 6 años

No matter what is left empty, you have to have the return without ice, just fresh

Responder
mrp2015
mrp2015
47
hace 6 años

The return freezes at the exit of the frizzer and I was controlling the temperature reaches -21 degrees and does not reach more, now I will try to remove coolant .. the two pressures at this time that the engine is stopped are 40 psi the high and low

Responder
sergiomorales00
hace 6 años
hace 6 años
Is it a well freezer? vertical? If you have access to the evaporator plate you can check the temperature difference between inlet and outlet, it must be less than 5 degrees to make sure the load is complete. However, download the app to the danfoss cell phone and it will control the temperature pressure ratio. The MO49plus is very effective, and in freezers you can work quietly in negative pressures. Keep the condenser clean, fix the filter that has a stable temperature and does not vary from one end to the other, check that the thermostat gets cut, and that's it. Slds!
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.84
(25)

Curso Práctico de Reparación y Bobinado de Motores Eléctricos

Héctor Castiñeira
$ 60 USD
$ 20 USD