Joséignacio33
hace 6 años
hace 6 años
Hello good afternoon. I have a problem with a Consul brand refrigerator, in the part of the freezer it freezes me on one side and not on the other and is at the maximum. If you can help me, what can you have? I appreciate it.
martin villegas
hace 6 años
hace 6 años
Jose Ignacio: may have one or more of the following failures, blockage by oil in the system, lack of gas, gas leak in the evaporator, perforation (s), but as far as you indicate the safest is that it has a lack of gas in your system, you can try to get more gas, and observe that there is no leakage of pressure in the system, if you notice that the price drops, you have one (or more) system perforations, or leak in the communication valve, by what you would have to do a vacuum to check that there are no leaks greetings and comments
Joséignacio33
hace 6 años

Thank you very much I will review those things. Then I told them I had. Hug

Responder
martin villegas
hace 6 años

Jose, did you find the leak? If not, first try to make it empty so that you do not spend gas, when you do it empty, go through the visible parts of the pipe with water and soap if there is luckily the leak, in case you finish and do not find it, that is It is in the inner pipe of the fridge. sometimes the concealed one can be removed and a new line can be inserted externally so as not to crack the refrigerator, in others the sheet can be carefully cut through where the pipe goes inside, search for leaks (s) to weld and test with vacuum, minimum of one day to the other (that does not lower the vacuum of the vacuum

Responder
martin villegas
hace 6 años

empty,) refill gas and rearm and see that it makes all its stops and starts your fridge, but before doing anything, tell your client the possible solutions to see which one he thinks so that you apply greetings and keep commenting

Responder
Joséignacio33
hace 6 años

I found the gas leak was in the pipe where the pressure check was done was broken. Thank you very much for your comments

Responder
Fermin 007
Fermin 007
57.307
hace 6 años
hace 6 años
Classic refrigerant failure due to leakage, greetings
Joséignacio33
hace 6 años

Hi ... how can I fix it since the leak must be in a non-visible place. Is there any liquid or can only be repaired by welding. Thank you

Responder
Fermin 007
Fermin 007
57.307
hace 6 años

Joseph
It is only solved by suldando and changing the damaged tube, greetings

Responder
Joséignacio33
hace 6 años

The tube that was damaged is the tube that is taken pressure and gas inlet was changed and was running. Thank you

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.84
(25)

Curso Práctico de Reparación y Bobinado de Motores Eléctricos

Héctor Castiñeira
$ 60 USD
$ 20 USD
4.94
(16)

Curso Refrigeración Comercial Aplicado a Diagnóstico y Reparación

Ing. Georga Melgarejo
$ 40 USD
$ 13 USD
4.71
(7)

Curso TV OLED y QLED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 29 USD
$ 10 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis