⚡ Descuentos en cursos en video - Lleva tu aprendizaje técnico al siguiente nivel y aprovecha precios especiales antes de que termine la oferta. 🔥 Aprovechar oferta ahora 🔥
Refrigerators

START WHEN YOU WANT is a Samsung nofrot mod.SR-57NXB

Monica Siri Delmaschio
hace 6 años
hace 6 años
The refrigerator when it is cold (I started doing an ICT every so often - one night I found everything defrosted, the ice cream. I was not walking, now I am seeing that the refrigerator vent that is in the form of a mailbox strip turns slowly - what do I do? THANK YOU
sergio cristo
hace 6 años
hace 6 años
Hello good afternoon . The first step is to know if there is voltage in ARGENTINA 220v in the outlet, then if the motor compressor starts. (The engine behind)
Monica Siri Delmaschio
hace 6 años

Hello, if it cools too, the voltage if 220 goes times low --- greetings

Responder
sergio cristo
hace 6 años

Hi . Did you say you hear a tick a sound this is behind the refrigerator ??? If so, you have problems in the relay that is in the engine. But since your refrigerator is a no frost, there is a great possibility that the temperature sensor is. It is usually behind the lid of the frezzer. Or where is the light in the refrigerator part.

Responder
Monica Siri Delmaschio
hace 6 años

THANKS I'm trying to see everything ---

Responder
Monica Siri Delmaschio
hace 6 años

the tic apparently comes out of the ball

Responder
sergio cristo
hace 6 años

If the tic leaves the ball, the simplest thing is to change relay and thermal protection are placed on the ball.

Responder
Monica Siri Delmaschio
hace 6 años

thanks Sergio, lotengo what to do!

Responder
Monica Siri Delmaschio
hace 6 años

no current reaches the thermal which can be ---? Thank you

Responder
Monica Siri Delmaschio
hace 6 años

no current reaches the thermal which can be ---? Thank you

Responder
sergio cristo
hace 6 años

Hello good afternoon . You are using alternating current. If it does not reach the thermal safe it is reaching the relay. It is indistinct. Check if you can if the relay and thermal protection have continuity, this is done with a tester.

Responder
Monica Siri Delmaschio
hace 6 años

THANK YOU --- all solved

Responder
sergio cristo
hace 6 años

You're welcome hits ????

Responder
friovega63
friovega63
11.849
hace 6 años
hace 6 años
Hi Monica, the first thing I tell you is that that called fan of corkscrews, is not the main fan, is really called multi-flow and its function is only to make a better distribution of cold air and does not work at high revolution, Your job is slow but fluid. The main fan is hidden in the frezzer, behind the plastic cover of what would be the back wall. The click that has been heard occasionally, could well be producing thermal protection when opening the passage of current to the compressor, by a failure of the relay or a capacitor of the compressor in case you use it, so it would have to be measured with a tester or multimeter, to check if one of them has been devalued, to the point of making the compressor sometimes not start correctly. Time can also test that kind of click, said Time, is a kind of clock that takes the equipment to defrost every 6 or 8 hours, to eliminate all the frost that is hidden in the evaporator (frezzer) of the system. If Time begins to fail, it obviously stops doing the aforementioned function and that implies that the refrigerator closes all the air ducts due to the excess of frost or ice that would accumulate, including the evaporator itself, while preventing Cold air flows throughout the interior of the equipment and obviously causing poor cooling of the food stored inside. If the refrigerator is now out of work, the thermal fuse that is connected in series with the defrosting resistor should also be checked, as well as the resistance itself that also opens, both elements are also hidden inside the frezzer and if they fail , they will also prevent feeding to the Time, causing in the same way the loss of cold. Check them out. To speed up defecation, use a domestic fan, disconnect the power supply and place the fan at the height of the frezzer and as close as possible to the entrance of the frezzer. This procedure is to speed up if you need to verify the good condition of the resistance or any other element inside the refrigerator. S @ lu2 friovega63.
Monica Siri Delmaschio
hace 6 años

Hello, very kind of you, thanks for what I learned, I did the fan thing, I started 4 seconds I heard TIC and the engine stopped - THANK YOU

Responder
friovega63
friovega63
11.849
hace 6 años

Already checked the relay, and the capacitors if you have them.

Responder
Monica Siri Delmaschio
hace 6 años

No, I will do that tomorrow. but from what I saw capacitors does not have -I reconnected it took 2 seconds and a tick was heard like coming out of the ball, did not start

Responder
friovega63
friovega63
11.849
hace 6 años

Hi Monica, if the voltage is getting right, definitely, or is the relay the problem or is the compressor itself damaged, although if there are moments that work well, everything points to the starter relay of the compressor, because the time when you disconnect the Sound is somewhat stronger, like a Tack and it is not a metallic click that is the sound that is heard by thermal protection when it shoots over consumption or temperature to protect the compressor. Time when it shoots or sounds, it takes a little more than 20 or 30 minutes to play Tack again, when it comes out of defrosting depending

Responder
Monica Siri Delmaschio
hace 6 años

Hello Friovega, I thank you and I tell you, now it does not start anymore, the metal click is heard nothing more ---- greetings

Responder
friovega63
friovega63
11.849
hace 6 años

Change the compressor relay.

Responder
Monica Siri Delmaschio
hace 6 años

hello, I have the relay and the thermal, as I measure them to see, they are fine THANKS

Responder
Monica Siri Delmaschio
hace 6 años

I do not get current to the thermal

Responder
friovega63
friovega63
11.849
hace 6 años

Monica, the team may have made a stop for defrosting and for that reason there is no power to the compressor. Go behind the equipment and to the left of the compressor, there must be a kind of plastic trunk, there is the Time inside, turn the plastic knob of the same in favor of the hands of the clock, to leave the defrosting process and ready try again to boot, but before. Finish changing the relay please, see if your cold is already stabilizing. For the love of God.

Responder
Monica Siri Delmaschio
hace 6 años

all solved ,,,, THANK YOU

Responder
friovega63
friovega63
11.849
hace 6 años

Hello Monica. I do not finally comment on the real cause of the problem. It is always good to know the results in details, this always conveys new experiences. Thanks for the comunication.

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.84
(25)

Curso Práctico de Reparación y Bobinado de Motores Eléctricos

Héctor Castiñeira
$ 60 USD
$ 20 USD
4.94
(16)

Curso Refrigeración Comercial Aplicado a Diagnóstico y Reparación

Ing. Georga Melgarejo
$ 40 USD
$ 13 USD
4.71
(7)

Curso TV OLED y QLED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 29 USD
$ 10 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis