Refrigerators

Capping of nevecom Samsung twin cooling capillary

Davila 79
hace 6 años
hace 6 años
Best regards friends. I have a Samsung twin cooling nevecom I made a change of compressor but I committed the serious terror of not replacing filter. Charging all BN and lowering temperature at 11 degrees in the freezing part, the pressure gauge went empty and stopped cooling, I opened the pressure gauge and no refrigerant came out, I made a small hole in the compressor outlet and the refrigerant knob was capping the capillary now as that type of systems is uncovered since those systems believe that they have an expansion valve and no liquid would pass Thank you for your help. Thank you
NG en linea
NG en linea
9.229
hace 6 años
hace 6 años
If you have a capillary, you should not have an expansion valve. The capillary does not always come off, it is better to change it although you can try with gas 141b cleaning agent introducing it with a syringe and then sweeping with nitrogen. Of course you have to disconnect the compressor lines. Change filter and empty before gas
Davila 79
hace 6 años

Friend I appreciate your help but since it is twin cooling it has two evaporators the 141b becomes liquid? As for the capillary goes internal and I don't know where it comes first if in freezing or cooling?

Responder
Fermin 007
Fermin 007
57.307
hace 6 años
hace 6 años
If you did not change filter there is the error, there is no need to change capillary tube, you have swept on both sides, evaporator and condenser and again the service, do not forget to change filter, it is very important and clear a good vacuum, luck
Davila 79
hace 6 años

Friend how much of a capillary this nevecom brings and what diameter is a double double evaporator door nevecom

Responder
Davila 79
hace 6 años

Amigo Fermín how many meters of capillary can I put to the Samsung twin cooling nevecom and of what diameter, since I definitely lost the fight with that uncap capillary but when the fridge reaches -13 it covers again I have spent a lot of gas and filter.
I appreciate your help

Responder

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.25
(8)

Reparación de Placa Main TV LED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 40 USD
$ 20 USD
4.6
(10)

Curso Localización de Fallas en Refrigeración en Heladeras/Neveras On/Off

Yamil Alarcón
$ 29 USD
$ 12 USD
4.64
(45)

Curso Tecnología Inverter - Fabricación de probadores y herramientas

Yamil Alarcón
$ 240 USD
$ 40 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis