Good friends greetings in advance. I would like to help me with this problem that I have with my LG 2-door refrigerator. To this refrigerator the compressor motor was changed she had a compressor motor of 1/5. Now I change it for a 1/6 engine. The fridge works well all day and part of the night. But there comes a time that the refrigerator stops by clock. And when starting the engine does not start. Bone turns on and off. But then that fault is removed and the engine works normally. I already took the current measurements and everything is fine. I hope my friends help me. And thank you very much in advance. There I send the images of the 1/5 and 1/6 engines
Fermin 007
Fermin 007
57.307
hace 6 años

If you cut the compressor by timer or clock and the defrosting lasts about 20 or 30 minutes, nothing to do with the thermostat, if after that rest time you put the compressor and want to start in several attempts and after those starts well, there are to check the relay, the thermal protector or the capacitor if it brings, but if they are good, it could be the compressor that already has problems or the refrigerant charge that maybe was passed since the compressor is smaller, greetings

Responder
lusangor
lusangor
56.366
hace 6 años
hace 6 años
Hello You have replaced the original compressor, with a smaller one, of less performance, which is not recommended The problem of not starting after resting, may be that this break is very short and the pressures inside the circuit have not stabilized, so it will not start until it stabilizes. if it is for a short time of rest, it can be by regulation of the thermostat very high, of the sensor (whatever you have, we have no model) or by the same compressor. Regards
juliofalcon
hace 6 años

Good friend regards. Very interesting your opinion really thank you very much. And if I understand the capacity. And good about the thermostat I have not changed. I have the original 1/6 engine thermostat. The thermostat you have at the moment is that of the 1/5 engine. I'm going to do that test to see how the function does. And really thank you very much friend greetings

Responder
lusangor
lusangor
56.366
hace 6 años

the thermostat, is the same for both compressors, what can be, is that it is uncalibrated and starts early

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.93
(14)

Curso Reparación de Equipos de Audio de Alta Fidelidad

Maximiliano Resch
$ 60 USD
$ 20 USD
4.84
(25)

Curso Práctico de Reparación y Bobinado de Motores Eléctricos

Héctor Castiñeira
$ 60 USD
$ 20 USD
4.64
(11)

Curso Electrónica para Reparación de Placas

Santiago Cediel
$ 29 USD
$ 11 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis