luiscataño
1.045
hace 6 años
hace 6 años
The wires that come out of the inverter card have the letters UVW but the motor terminals have no identification, my question where I connect each of them in the image we can see that in the motor apart from the power cables it should carry I suppose a fuse but It does not say its capacity please can you help me
Fermin 007
Fermin 007
57.307
hace 6 años
hace 6 años
The right terminal is the U The Isquierdo W terminal The central or common terminal is V The inverter compressor control is similar to that of a conventional compressor, that you have to buy ORIGINAL for that compressor.
luiscataño
luiscataño
1.045
hace 6 años

Friend excuse my ignorance but in a conventional starter kit we have COMMUN, START AND START, in this case what the gear is, where the U goes to the right and the W is the start
I thought I would take the thermal protector only, and the other direct wires to the U and W terminals

Responder
Fermin 007
Fermin 007
57.307
hace 6 años

Exact¡¡¡¡¡ U march, W starter coil and V common and has a control that comes from the card, is similar to the conventional ptc relay, with thermal protector, that would have to buy, not connect directly to the terminals

Responder
Fermin 007
Fermin 007
57.307
hace 6 años

I need not connect the 2 cables directly to the UYW terminals

Responder
luiscataño
luiscataño
1.045
hace 6 años

Amigo Fermin 007 thanks for the feedback, I comment these motors are THREE-PHASE, therefore they should not carry a gear relay, if you must carry a thermal protector on the motor or (fuse in the power of the inverter card as shown in the plan)

Responder
Fermin 007
Fermin 007
57.307
hace 6 años

Correctisimo, the thermal protector, carries it in the common terminal in this case V and the other 2 terminals the controller that comes from the card, rectified, is not a relay like conventional compressors, the controller box is rectangular, greetings

Responder
luiscataño
luiscataño
1.045
hace 6 años

Fermin please could you send me the photo of one if you have it please or the number or as I buy what is the technical name

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.84
(25)

Curso Práctico de Reparación y Bobinado de Motores Eléctricos

Héctor Castiñeira
$ 60 USD
$ 20 USD
4.71
(7)

Curso TV OLED y QLED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 29 USD
$ 10 USD
4.64
(11)

Curso Electrónica para Reparación de Placas

Santiago Cediel
$ 29 USD
$ 11 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis