Friend excuse my ignorance but in a conventional starter kit we have COMMUN, START AND START, in this case what the gear is, where the U goes to the right and the W is the start
I thought I would take the thermal protector only, and the other direct wires to the U and W terminals
Exact¡¡¡¡¡ U march, W starter coil and V common and has a control that comes from the card, is similar to the conventional ptc relay, with thermal protector, that would have to buy, not connect directly to the terminals
Amigo Fermin 007 thanks for the feedback, I comment these motors are THREE-PHASE, therefore they should not carry a gear relay, if you must carry a thermal protector on the motor or (fuse in the power of the inverter card as shown in the plan)
Correctisimo, the thermal protector, carries it in the common terminal in this case V and the other 2 terminals the controller that comes from the card, rectified, is not a relay like conventional compressors, the controller box is rectangular, greetings
Fermin please could you send me the photo of one if you have it please or the number or as I buy what is the technical name