Fridge Gafa no frost stops cooling. Humidity in the system?

Flavio Villanueva
hace 6 años
hace 6 años
I have a Gafa No Frost refrigerator to which I change my compressor for a used one with the same characteristic, filter, capillary, perform cleaning with 141B, barrel with nitrogen, pressurize, perform the corresponding vacuum of 1 hour, finished these processes I put it in and after two days I stop cooling, I connect the pressure gauge and I was working at almost 25 inches of HG, I reactivate the whole procedure and the same thing happens again, in this case I decide to heat the capillary at the entrance to the evaporator and listen to the typical noise of evaporation, obviously I have moisture, the serious question, what do you recommend to extract all that moisture? It should be noted that the motorcycle was a week uncovered in its low and high pipes. Thank you.
davidefrainrod
hace 6 años
hace 6 años
Hello flavio if you really say that the pipes were open almost a week, how do you think that this will work without problems? Now you will have to take out a compressor again, turn it out and discard all the oil ((without throwing it in the environment)) Clean system with R141 and make a sweep and change filter since it sure got wet too and just there was a good vacuum and loaded with gas. Be very careful since the oil is moistened in about 15 minutes if it is POE and a little more if it is alkylbenzene. With this I want to tell you to do the following clean everything and assemble everything again but the compressor that is oil free once it is all welded and you tried not to leak just there you make a short 20 min short and just there with a Hose of the same manifold you get the oil that will suck through the same vacuum that has the compressor then continue with the normal vacuum and gas charges. regards
Flavio Villanueva
hace 6 años

As was your comment, I made everything and it was perfect, thank you very much for your collaboration. Regards.

Responder
davidefrainrod
hace 6 años

Ok luck greetings

Responder
Pablotec.ar
hace 6 años
hace 6 años
Hi, what do you mean with 25 hg pulls?
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.73
(22)

Curso Reparación de Fuentes Conmutadas de PC y Equipos Electrónicos

Maximiliano Resch
$ 40 USD
$ 20 USD
4.87
(15)

Curso Diseño de Amplificadores de Máxima Fidelidad

Maximiliano Resch
$ 29 USD
$ 13 USD
4.71
(7)

Curso TV OLED y QLED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 29 USD
$ 10 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis