Hi Reegue, there is a lot of difference between both capacities of about 275 btu / h, approximately more than a quarter of the total in refrigeration capacities, which would lead to the total change of the entire refrigeration system of your refrigerator, so in addition to changing The compressor should also replace the condenser and evaporator or freezer. For what I recommend, it is better to look for a compressor that has the same refrigerating capacity as the original of your refrigerator, no matter brand or manufacturer, that was, for about 650 btu / h, approximately 1/6 + Hp. Luck. S @ lu2 friovega63.
Hi Reegue, thanks to you for the communication. 1Ph means that they are single-phase compressors, if they were three-phase they would say 3Ph. Hp comes from power and Ph from phases. Luck. S @ lu2 friovega63.