What type of capillary do you wear?
friovega63
friovega63
11.849
hace 6 años
hace 6 años
Hi Reegue, for that compressor of approximately 925 btu / h, of refrigerating capacity 1/4 + Hp should use, 1-) a capillary with an inside diameter of 0.80 mm, with 1750 mm in length. 2-) one of inner diameter of 0.90 millimeters, with 3150 millimeters in length. 3-) one of inner diameter of 1.00 millimeters, with 5150 millimeters in length. You can use any of these measures, as appropriate, for a freezer or refrigerator. Luck. S @ lu2 friovega63.
Reegue
Reegue
4
hace 6 años

I want to mount it to a domestic refrigerator, its original compressor was clutch EGU 60hlc thanks for such a quick response and I want to know if the one I told you works well for me

Responder
friovega63
friovega63
11.849
hace 6 años

Hi Reegue, there is a lot of difference between both capacities of about 275 btu / h, approximately more than a quarter of the total in refrigeration capacities, which would lead to the total change of the entire refrigeration system of your refrigerator, so in addition to changing The compressor should also replace the condenser and evaporator or freezer. For what I recommend, it is better to look for a compressor that has the same refrigerating capacity as the original of your refrigerator, no matter brand or manufacturer, that was, for about 650 btu / h, approximately 1/6 + Hp. Luck. S @ lu2 friovega63.

Responder
Reegue
Reegue
4
hace 6 años

Thank you very much for your efficient response. I will look for a compressor of the same capacity. (Both compressors claim to be from an HP that is that)

Responder
Reegue
Reegue
4
hace 6 años

Sorry 1ph

Responder
friovega63
friovega63
11.849
hace 6 años

Hi Reegue, thanks to you for the communication. 1Ph means that they are single-phase compressors, if they were three-phase they would say 3Ph. Hp comes from power and Ph from phases. Luck. S @ lu2 friovega63.

Responder
Reegue
Reegue
4
hace 6 años

Thanks again for clarifying something I was wrong about changing the compressor

Responder
friovega63
friovega63
11.849
hace 6 años

We're at your service. S @ lu2 friovega63.

Responder

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.93
(14)

Curso Reparación de Equipos de Audio de Alta Fidelidad

Maximiliano Resch
$ 60 USD
$ 20 USD
4.25
(8)

Reparación de Placa Main TV LED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 40 USD
$ 20 USD
4.64
(45)

Curso Tecnología Inverter - Fabricación de probadores y herramientas

Yamil Alarcón
$ 240 USD
$ 40 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis