Timer stops turning when entering stop by thermostat.

Reies Jorgge
hace 6 años
hace 6 años
Good day, I have a detail with my refrigerator, the timer it has is 10 hours but when it comes to a standstill by means of the thermostat (30 min) the timer stops turning. Then it happens that if during that period of 10 hours the refrigerator makes thermostat shutdowns several times, it will no longer thaw in 10 hours if not up to 15 hours approx. DOUBT: Is it normal for the timer to stop turning on the compressor stops by thermostat? NOTE: While the compressor is running, the timer rotates continuously without problem.
friovega63
friovega63
11.849
hace 6 años
hace 6 años
Hi Reies, it's completely normal, and as long as it doesn't produce ice buildup on the evaporator coil, everything would be fine. You must be sure that this timer model is the one that originally carries your refrigerator, since the most commonly used timers are used in defrosting systems, which make the timer stop, due to its electrical connection, every time the thermostat is cut, They turn out to be the 6 hour timer. Luck. S @ lu2 friovega63.
Fermin 007
Fermin 007
57.307
hace 6 años
hace 6 años
The thermostat cut causes the timer motor to be cut, its operation is NORMAL, do not worry, regards
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.25
(8)

Reparación de Placa Main TV LED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 40 USD
$ 20 USD
4.87
(15)

Curso Diseño de Amplificadores de Máxima Fidelidad

Maximiliano Resch
$ 29 USD
$ 13 USD
4.64
(45)

Curso Tecnología Inverter - Fabricación de probadores y herramientas

Yamil Alarcón
$ 240 USD
$ 40 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis