⚡ Descuentos en cursos en video - Lleva tu aprendizaje técnico al siguiente nivel y aprovecha precios especiales antes de que termine la oferta. 🔥 Aprovechar oferta ahora 🔥
Refrigerators

what is the thin wire that comes out of the regulator for?

abejes
abejes
1
hace 6 años
hace 6 años
i have a pallet fridge and from the regulator comes out a wire and i don't know what's it for and i moved it and it came out, i need you to tell me where i have to connect it, and the fan slides and sometimes it doesn't spins, i have to help it, spining it myself and it makes a lot of noise, please tell me how to fix it, thank you in advance and good day.
cesar augusto cerna
hace 6 años
hace 6 años
Hello: the wire that you say could be the thermostat, that you call regulator,that one only brings inlet and outlet, you only have to connect it.Now if the fan does not turns on fine, it may be that the bushings of the shaft are worned out and need to be replace.You should also check the capacitor, maybe it's ruined and need to be changed.Greetings.
abejes
abejes
1
hace 6 años
hace 6 años
cesar augusto cerna
hace 6 años
hace 6 años
Hello: What you're talking about is the capillary of the thermostat, that goes fixed in the fridge, find where it was entrenched, it should have a little plate and two screws, it is the one that measures the temperature, check it, it isn't wire it's a capillary, hollow and it brings gas inside, be careful when you manipulate it.Greetings.
abejes
abejes
1
hace 6 años
hace 6 años
Ok and you think that for that the regulator, the thermostat and the temperature knob were not working fine, ok let me check it in the afternoon and i tell you tomorrow, the other thing is that the fan makes a lot of noise and i have to push it manually, do i have to change the bushings or do i have to buy a new one?I really thank a lot the help you give me.Well, abusing of your knowledge, i have another pallet fridge 1.70 length and i have the problem that it only freezes or cools in one wall of 1.70 and other of 60 cm, so it only cools in two walls that form a 90 degree angle and the other two walls do not cool, do you have any idea what it could be?, in advance, thank you a lot for your attention, i owe you.
cesar augusto cerna
hace 6 años
hace 6 años
The main thing is to try pressures of the compressor, if it is okay, what's next is to clean the system, change the dehydrator filter, weld, put pressure to tyr leaks, make empty and load.As fr the fan engine, if you have th chance, replace it, if not, repair it, new is always better and guaranteed.Good luck and greetings.
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.87
(15)

Curso Diseño de Amplificadores de Máxima Fidelidad

Maximiliano Resch
$ 29 USD
$ 13 USD
4.71
(7)

Curso TV OLED y QLED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 29 USD
$ 10 USD
4.64
(11)

Curso Electrónica para Reparación de Placas

Santiago Cediel
$ 29 USD
$ 11 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis