⚡ Descuentos en cursos en video - Lleva tu aprendizaje técnico al siguiente nivel y aprovecha precios especiales antes de que termine la oferta. 🔥 Aprovechar oferta ahora 🔥
Refrigerators

LG fridge fails

Amadojose88
hace 6 años
hace 6 años
I have an LG Mod-GR46n62CVC fridge, I connect it and it starts working but the LED lights are on only one of the 5 previously marked the first three and it works well that could be that fault
lusangor
lusangor
56.366
hace 6 años
hace 6 años
Hello If you have stopped the fridge, it may not have reached the temperature that was previously regulated, wait 24 hours for it to stabilize and check regards
friovega63
friovega63
11.849
hace 6 años
hace 6 años
Hi Amadojose88, so he says, if you press the button or micro switch that makes the temperature changes in the panel where it has the 5 LEDs and does not allow you to make variations on them, because that only led has been fixed, everything would be indicating a Possible error code in your fridge, which depending on the LED that has been fixed on, we can know to which error it belongs and where to go to find the fault. The 5 LEDs are numbered from minimum to maximum such as (R0, R1, R2, R3 and R4) 1- (Yes, the LED (R2) that would actually be the third LED counting from minimum to maximum is fixed, if you stand in front of the refrigerator and counting from left to right, this would also be in the center of the 5 LEDs, this LED would indicate a fault in the temperature sensor of the conservation or cooling zone 2- (Yes the led number (R3) is fixed which would be the fourth LED from minimum to maximum, it would indicate a fault in the defrost sensor, located in the area of the freezer attached to the evaporator coil.This sensor if measured at a constant temperature of 25 degrees Celsius must report a value of Approximately 11 kilo ohm, if we also place the multimeter, on the 20 kilo ohm scale, to make its measurement more precise, this error could also indicate a fault in the rest of the control system on the electronic board, but first it must be measured the sensor, which is always the first failure in these cases most common of these equipment. Luck. S @ lu2 friovega63.
Amadojose88
hace 6 años

Thank you very much according to your excellent explanation everything leads to the failure is the LED (R3) that would be the failure of the Michas refrigerator Thank you !!!!

Responder
friovega63
friovega63
11.849
hace 6 años

Thank you for the communication. S @ lu2 friovega63

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.84
(25)

Curso Práctico de Reparación y Bobinado de Motores Eléctricos

Héctor Castiñeira
$ 60 USD
$ 20 USD
4.71
(7)

Curso TV OLED y QLED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 29 USD
$ 10 USD
4.64
(11)

Curso Electrónica para Reparación de Placas

Santiago Cediel
$ 29 USD
$ 11 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis