Maxidagos
hace 6 años
hace 6 años
Good morning, I have a problem with a compressor q I lost coolant x the suction and the hopper of the hopper, and I wanted if I could explain how these robins work, if it is only to access with a manometer or close the coolant passage .... and how to solve my problem of loss, thank you very much
CHIALVA JESUS ERNESTO
hace 6 años
hace 6 años
the rovinete when you give it a little clockwise gives you access to the reading in the manifol and if you carry it thoroughly clockwise closes the coolant passage, so that it is working the device you must take the rovinete totally counterclockwise, check which have a bronze nut that you can adjust and stop losing, for that nut passes the stem, luck
Maxidagos
hace 6 años

Thank you very much for your help