⚡ Descuentos en cursos en video - Lleva tu aprendizaje técnico al siguiente nivel y aprovecha precios especiales antes de que termine la oferta. 🔥 Aprovechar oferta ahora 🔥
Refrigeration

The mabe fridge makes ice

ralesme
ralesme
14
hace 6 años
hace 6 años
I am a technician, I have a card mabe fridge that was already seen by other technicians and they did not find the problem, it turned out that the entire electrical installation in the freezer was cut off. I adapted a 6-hour timer, the connection was made from the card as follows: it has an orange, brown, black, blue wire. Orange goes to 3, coffee to 1, black to 4, and blue to 2, but since I don't have the bimetallic installation and resistance I did the following: from orange I took out a cable for the bimetallic and from this I connected another towards the resistance, of the blue cable connect a cable towards the resistance I put the fridge to work and it is freezing, I ask for a help so that the refrigerator does not block me of ice please.
Elio Maffei
hace 6 años
hace 6 años
IMAGE 7.jpg [20.59kb] Ralesme. The photo is not focused and the question is not clear.-What do you want to know? How can you help with what you wrote? nothing is understood Start by writing what you want to solve, then write the data of the refrigerator, if it is 2 vertical door or floodgates up and down, if the freezer is up, down or sideways, some photos, the problem that the refrigerator has a photo of the defrost card and photo of how you installed the clock with the card. Normally if a stop clock is added, it works with defrosting and the card starts the engine again by turning off the clock until the next stop, so the card controls the clock and the clock defrosts it with the time the card gives it keeping the resistance on until the ice is removed and the bimetallic sensor turns off the resistance. Load more data please I can't copy the plane of the refrigerator and yours is blurry, in which I opened, I think it's the same, Starting at the entrance. Orange is the common for everything (neutral) and on the left side the coffee is the phase for everything. Orange enters the evaporator fan and on the other side has a black wire that goes through the door's suiche and goes to terminal O of the electronic card and also goes to the bimetallic of the compressor and the common one of the same, bone of the card feeds with black compressor and evaporator fan the ORANGE enters the electronic card in terminal N the solito The ORANGE enters the BIMETALIC, leaves with PINK to the RESISTANCE where it leaves with BLUE and goes to the D of the card The brown cable of the DIRECT line enters the terminal L of the card If you still have the card in place, these are the connections you have to make even if you have used different colored cables, you must respect the connection plan
ralesme
ralesme
14
hace 6 años

It is not that, I explain to this refrigerator the installation where the resistance and the bimetallic of the freezer is connected and it has on the left side a piece of orange cable with a black one and on the right side another piece of orange cable I want to know how it is known the resistance and the bimetallic with those cables since the diagram shows the resistance connected with blue cable and in the frrezer it is not.

Responder
ralesme
ralesme
14
hace 6 años

That connects the orange wire of the mabe fridge

Responder
Elio Maffei
hace 6 años

I already heard you more clearly how the connections are going. try not to set the clock if the card works, it should work fine s
control the bibetal and resistance that work so you don't go crazy. I wrote to you how the card on that side is connected, on the other side the electronic display is connected. I hope that now if you do it and give me points please

Responder
Elio Maffei
hace 6 años

Everything I wrote to you above in the proposed solution and the previous comment is a postscript

Responder
ralesme
ralesme
14
hace 6 años

the orange connects to the bimetallic and coffee goes to the neutral, the resistance goes to 2 of the timer and the black goes to 4

Responder
ralesme
ralesme
14
hace 6 años

I want to make an installation of the alternative defrosting system since that of the refrigerator does not work I want you to make me a scheme to be able to make it work the bimetallic and the resistance when the timer rests the mebe cables are the blue that is not , coffee, orange, black

Responder
Elio Maffei
hace 6 años

Tell me, I made the drawing, but when you photograph and load it it looks blurry, so I put a link <yo reparo > where there is a drawing to remove the card and put a timer and a thermostat ------- https://yoreparo.com/refrigeracion/refrigeradores/preguntas/557677/adaptar-timer-a-refrigerador-mabe-con- card ------- here are other links for you to learn https://fallaselectronicas.com/refrigerador-no-frost-lg-tarjeta-electronica-quemada/

Responder
ralesme
ralesme
14
hace 6 años
hace 6 años
Give me a scheme of how I can connect the resistance and the bimetallic timer with an alternate connection from which the refrigerator brings since all the wires that connect up in the freezer
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.93
(14)

Curso Reparación de Equipos de Audio de Alta Fidelidad

Maximiliano Resch
$ 60 USD
$ 20 USD
4.71
(7)

Curso TV OLED y QLED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 29 USD
$ 10 USD
4.64
(11)

Curso Electrónica para Reparación de Placas

Santiago Cediel
$ 29 USD
$ 11 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis