⚡ Descuentos en cursos en video - Lleva tu aprendizaje técnico al siguiente nivel y aprovecha precios especiales antes de que termine la oferta. 🔥 Aprovechar oferta ahora 🔥
Refrigeration

Counter refrigerator

Rodo.argentino
hace 6 años
hace 6 años
Good friends ... I am making my first weapons in the field and would need to get me out of a doubt, they called me by a counter refrigerator with capillary expansion system which has the broken motor compressor ... is 1 / 2hp in r22. .and the owner got one mc of the same power but for r12..my doubt is if I could install and load it with r22 again without problems, thank you very much.
omorma
omorma
15.708
hace 6 años
hace 6 años
Hello how are you, you have to clean the system with 141b and nitrogen change the filter and then load with any replacement of R12 mp39 for example (r401) should not be loaded with r22 greetings.
Rodo.argentino
hace 6 años

Thanks for responding omorma ... so you don't need to modify the capillary or anything, right?

Responder
omorma
omorma
15.708
hace 6 años

No need, slow charge and test with time checking the temperature

Responder
Rodo.argentino
hace 6 años

Thank you!!!

Responder

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.84
(25)

Curso Práctico de Reparación y Bobinado de Motores Eléctricos

Héctor Castiñeira
$ 60 USD
$ 20 USD
4.87
(15)

Curso Diseño de Amplificadores de Máxima Fidelidad

Maximiliano Resch
$ 29 USD
$ 13 USD
4.64
(45)

Curso Tecnología Inverter - Fabricación de probadores y herramientas

Yamil Alarcón
$ 240 USD
$ 40 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis