Air conditioner

Air conditioning

Gaston
Gaston
2
hace 5 años
hace 5 años
Dear, good afternoon. I have a split of 4500 calories. The problem I have is that it costs a lot to compress the gas. The load is perfect and I measured the amperage and it is the right one, at no time it goes off, the capacitor is perfect. When I leave it comes to 0 and there begins to slowly increase the compression. What can you see? The air was approximately 3 years stopped. Thank you. Regards!
TRIATLON99
TRIATLON99
6.267
hace 5 años

Does the pressure increase? What does the load is perfect? What amperage do you have?
Comment

Responder
NG en linea
NG en linea
9.229
hace 5 años

What pressure does it reach?

Responder
Gaston
Gaston
2
hace 5 años

45 I already charged gas to reach 60 and now there is no way to arrive.

Responder
Gaston
Gaston
2
hace 5 años

If the pressure increases to 45 but it takes a lot. The load is perfect and works in 8amper

Responder
elektomaq
elektomaq
62.202
hace 5 años

The only way to confirm with such certainty that the load is perfect is if it was loaded to the weight, otherwise there is no perfect one and if you want us to help you you will have to be a little more specific and not draw conclusions

Responder
Gaston
Gaston
2
hace 5 años

Dear, the air was loaded according to the kilos it says on the label next to it. My question is why when I turn it to zero and very slowly it begins to compress? Could it be that the compressor is damaged? Capped capillary tube?

Responder
elektomaq
elektomaq
62.202
hace 5 años

How many meters of pipe do you have between units?

Responder
Gaston
Gaston
2
hace 5 años

The unit is connected to a pipe meter. Since I have it testing without mounting it to the wall.

Responder
NG en linea
NG en linea
9.229
hace 5 años
hace 5 años
Hi. In noemal when you start a team that goes up slowly, provided that this reaches to yield with the temperature that is ezpera With tupition in the system the needle tends to go empty.
Gaston
Gaston
2
hace 5 años

The cold output that I have through the mouth of the indoor unit is 22 ° C should not be less? I am surprised that it takes 20 min to reach the desired compression.

Responder
elektomaq
elektomaq
62.202
hace 5 años
hace 5 años
On the one hand it can be said that it is normal for it to descend to about 0 and slowly rise until normalized, this process can take 1 or 2 minutes According to the mentioned data, if the pressure does not normalize, some reasons to review are slow indoor fan speed Serpentine dirty indoor unit Dirty turbine Dirty filters System obstruction Strangulation of lines Badly open bearings I would not go for the lack of compression since this generates the opposite effect Cheers
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.73
(22)

Curso Reparación de Fuentes Conmutadas de PC y Equipos Electrónicos

Maximiliano Resch
$ 40 USD
$ 20 USD
4.6
(10)

Curso Localización de Fallas en Refrigeración en Heladeras/Neveras On/Off

Yamil Alarcón
$ 29 USD
$ 12 USD
4.94
(16)

Curso Refrigeración Comercial Aplicado a Diagnóstico y Reparación

Ing. Georga Melgarejo
$ 40 USD
$ 13 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis