Air conditioner

mini split compressor does not turn on

puente roto
hace 5 años
hace 5 años
good afternoon! replace a 24000btu compressor, perform the entire standard procedure, only when the refrigerant refill is turned off and no longer turns on. I reach 40 PSI of pressure and 7 A of consumption. The only thing that is suspicious is that the compressor was delivered to me lying down and I suspect it was turned over. What I can do?
puente roto
hace 5 años

It is a new compressor, when touched it is very hot but not unusual. my doubt is if it could have affected the one that was upside down by the accumulation of oil in the discharge

Responder
omorma
omorma
15.708
hace 5 años
hace 5 años
Hi, how are you? I would try connecting the compressor directly to discard it, it's not locked, greetings.
luiscataño
luiscataño
1.045
hace 5 años
hace 5 años
Test the compressor coils, if they are good, disconnect the compressor terminals and the capacitor starts the motor and check if the voltage reaches the COMMON AND RUN terminals, if the voltage is well measured by the capacitor, in some of these steps there must be a failure
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.93
(14)

Curso Reparación de Equipos de Audio de Alta Fidelidad

Maximiliano Resch
$ 60 USD
$ 20 USD
4.84
(25)

Curso Práctico de Reparación y Bobinado de Motores Eléctricos

Héctor Castiñeira
$ 60 USD
$ 20 USD
4.94
(16)

Curso Refrigeración Comercial Aplicado a Diagnóstico y Reparación

Ing. Georga Melgarejo
$ 40 USD
$ 13 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis