⚡ Descuentos en cursos en video - Lleva tu aprendizaje técnico al siguiente nivel y aprovecha precios especiales antes de que termine la oferta. 🔥 Aprovechar oferta ahora 🔥
Air conditioner

Daewoo 3000fg sensors

Andres escande
hace 5 años
hace 5 años
Hello group. My query is the following. The equipment marked an f8 fault that corresponds to the serpentine sensor changed it by a 10k .. error came out but the equipment starts and within a few minutes the condenser stops .. the sensor 5k atmosphere will be there the problem .. thanks. and there a third sensor that goes to the condenser. should be when used in winter .the equipment ??
omorma
omorma
15.708
hace 5 años
hace 5 años
Hello how are you, try one of 5k may be that the problem and that of the condenser can be defrost and connects with a tab that comes from the indoor unit and another sensor is compressor discharge temperature greetings.
Andres escande
hace 5 años

Thank you. I will and I will tell you

Responder
Andres escande
hace 5 años
hace 5 años
Hello good people I tell you if the solution was to place one of 5k just like the ambient sensor. And I also make it clear that in this equipment the faults F8 is a coil or pipe sensor .. F7 environment sensor and F6 problems in the Cooler either for being braked or capacitor .. give you thank you very much for sharing air daewoo 3000 fr / cold heat

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.84
(25)

Curso Práctico de Reparación y Bobinado de Motores Eléctricos

Héctor Castiñeira
$ 60 USD
$ 20 USD
4.87
(15)

Curso Diseño de Amplificadores de Máxima Fidelidad

Maximiliano Resch
$ 29 USD
$ 13 USD
4.64
(11)

Curso Electrónica para Reparación de Placas

Santiago Cediel
$ 29 USD
$ 11 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis