Air conditioner

failure in centralized housing aacc (cools but does not heat)

javierperea
hace 5 años
hace 5 años
I have a centralized aacc in my mitsubishi DAIYA brand home, the point is that when summer comes it cools (although not excessively), but when winter comes it does not heat anything at all. A technician came and only observed that the problem should be due to the fact that the fan that is installed on the roofs was semi-overturned as a result of a poor attempt the day it was set, apparently because the technician who took care of it placed the fan on a wooden mini pallet, which over time and the weather (rain, etc) ended up breaking the semi-overturned device. As this technician told me that he would charge me for the 350 euros I told him not to fix it since he would try to solve it with the store that installed it, who has finished washing his hands for having already spent 16 years. Well, my question is that if I could put it straight by removing the pallet and leaving it like the rest of the devices found there, if I had to touch any other conduit, if there could be a leak with the data that I have provided the cold works but not the heat, or is it something punctual where I should look? I know that it is very difficult to give help without making the device visible, but given the economy I have to try myself if its repair is easy and possible. I would appreciate any comments on whether I have to look at a particular conduit or observation to take into account in this regard, attached a photo that I could take, thank you very much in advance
alpablape
alpablape
102
hace 5 años
hace 5 años
friend in my opinion that is not even remotely the problem, you can level it and it is something minimal that I do not consider to affect! I have not worked with these airs of heating but if I am almost sure that in the heat mode the compressor should not work and a resistance must be activated by which the cold air of your room is sucked into hot air, that must be the starting point to check! I hope my comment is useful!
javierperea
hace 5 años
hace 5 años
Thank you very much for your response, I understand that the only and only resistance must be checked by a technician, thank you
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.25
(8)

Reparación de Placa Main TV LED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 40 USD
$ 20 USD
4.6
(10)

Curso Localización de Fallas en Refrigeración en Heladeras/Neveras On/Off

Yamil Alarcón
$ 29 USD
$ 12 USD
4.64
(11)

Curso Electrónica para Reparación de Placas

Santiago Cediel
$ 29 USD
$ 11 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis