hace 5 años
Hi colleagues in the forum I need to know if the length of the installation kit that the split-type A / A equipment manufactures influences, that is, I know that they come with a minimum of 3 meters and my doubt is if this distance can be reduced and if it It would cause some damage to the equipment. I would also like to know the maximum allowed distance between the condensing unit and the evaporator. Thanks in advance
TRIATLON99
TRIATLON99
6.267
hace 5 años
hace 5 años
Hello, the product warranty requires 3 meters in terms of operation with more than 1.50 meters without problems (talking with refrigerant r 410 a). The maximum pipe length is specified by the user manual in some cases up to 12 meters or more, at a greater distance than required, refrigerant is added. regards
Joe
Joe
Joe
93
hace 5 años

Any technique to add refrigerant when the distance increases?

Responder
TRIATLON99
TRIATLON99
6.267
hace 5 años

Also specified in the manual, are 20 or 30 grams depending on the pipe in split equipment for each additional meter.

Responder
Joe
Joe
Joe
93
hace 5 años

thanks a thousand for the help, tell me if it is possible to bring that data to pressure, that is, I only have a manifold set for r410a

Responder
TRIATLON99
TRIATLON99
6.267
hace 5 años

Working pressure 100/120 psi according to ambient temperature at higher temperature plus pressure.
The equipment must work 15 ', controls the pressure and if necessary add refrigerant.
regards

Responder
Joe
Joe
Joe
93
hace 5 años

super grateful

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.25
(8)

Reparación de Placa Main TV LED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 40 USD
$ 20 USD
4.87
(15)

Curso Diseño de Amplificadores de Máxima Fidelidad

Maximiliano Resch
$ 29 USD
$ 13 USD
4.94
(16)

Curso Refrigeración Comercial Aplicado a Diagnóstico y Reparación

Ing. Georga Melgarejo
$ 40 USD
$ 13 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis