⚡ Descuentos en cursos en video - Lleva tu aprendizaje técnico al siguiente nivel y aprovecha precios especiales antes de que termine la oferta. 🔥 Aprovechar oferta ahora 🔥
Air conditioner

Air conditioning fan motor

jose ricardo osuna
hace 5 años
hace 5 años
Hi, I need suggestions. The fan motor of my Surrey brand window air conditioner stopped working, so I disassembled it and I lubricated it, it was very light and it has a little play in the bushings, the issue is that I have to help you with your hand so that start if or if or if it is buzzing, now I want to know if it is for that little game that has not start alone or if I would have to check something else, for example measure something if so tell me I have to measure and how to please. The capacitor is not because I tried even with one of greater uf and does the same, could you guide me? From already thank you very much
Castelar
Castelar
222
hace 5 años

If you have tried it with another capacitor and the symptom remains the same, then it is possible that the starter coil is damaged.

Responder
jose ricardo osuna
hace 5 años

And if so, how can I measure the coil if you can explain to me please? Sorry for the inconvenience.

Responder
NG en linea
NG en linea
9.229
hace 5 años
hace 5 años
Hi . It may be the winding, but di has a lot of play in the bushings or ball boxes can also cause that problem because the rotor sticks to the fields.
jose ricardo osuna
hace 5 años

And you saw that it is not much the game that it has but it can be, now another thing as I do the winding measurement if you can explain to me sorry for the inconvenience?

Responder
Castelar
Castelar
222
hace 5 años

I do not know the Ohm's of its motor, and not having this data complicates the detection of the fault. What I do is put a capacitor that works and if it does not start you have to wind it and change the bushings. Greetings and luck.

Responder
NG en linea
NG en linea
9.229
hace 5 años

Take it to a workshop to be measured

Responder
jose ricardo osuna
hace 5 años

Thank you sir for your help I will consider you greetings

Responder
friovega63
friovega63
11.849
hace 5 años
hace 5 años
Hi José, the measurements to know if the motor is in good condition or not, are quite simple, you just need to have a multimeter and place it preferably on the diode reading scale, then you must proceed to measure one by one, each of the motor cables, all among all, for example you must choose any color and the rest of the cables must have or mark a resistance reading with the other cable colors, and so on, I repeat all against all, yes one of the measures do not work out, because the multimeter does not mark anything, in that case the motor would be damaged in your winding and you would have to send it to rewind with a specialist. if all the cables have continuity with each other, in that case I should assess the comments of my colleagues, about the condition of the bearings or of the capacitor itself, if the equipment was already recently intervened by a technician, it may have varied the connection of the cables, so if in doubt you can keep asking and I explain how to know the connection of each cable, which for a better explanation, I would need to provide the colors of cables, their values among all and if you have the electrical diagram of the equipment and the engine itself does have it outside its housing. Luck. S @ lu2 friovega63.
jose ricardo osuna
hace 5 años

Thank you very much for your very complete contribution, you can learn well because it is very clear, congratulations and again thanks, greetings

Responder
Castelar
Castelar
222
hace 5 años

To know the Omn's of a motor winding, an "Impedance" reader is used.

Responder
friovega63
friovega63
11.849
hace 5 años

Thank you José for your assessment and thanks for the communication. S @ lu2.

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.25
(8)

Reparación de Placa Main TV LED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 40 USD
$ 20 USD
4.87
(15)

Curso Diseño de Amplificadores de Máxima Fidelidad

Maximiliano Resch
$ 29 USD
$ 13 USD
4.94
(16)

Curso Refrigeración Comercial Aplicado a Diagnóstico y Reparación

Ing. Georga Melgarejo
$ 40 USD
$ 13 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis