Error E3 on universal plate air 3000 frig r410

Lisandro Raffin
hace 5 años
hace 5 años
Hello, I had problems with the outside fan of my split (it turned off and the compressor cut by thermal) what I did was replace the platelet since it stopped sending me tension towards the outside fan, and I placed a universal one, now the problem is that in the universal I get error E3 but the air works and does not cut the outside fan. Another problem is that I did maintenance and reinstalled it, I measured and it lacked refrigerant, I charged it and the air cooled but not enough. in 26 degrees the compressor cuts but not the fan, and in 24 it does not cut directly, it lacks cold I measured overheating at the inlet and outlet of the evaporator and it gives me at the entrance 17 degrees and the exit 12 degrees Will I lack coolant or did I go over? The equipment with 33 degrees of ambient temperature works in low to 150 psi With the calculations I did is enough, I want to remove all the refrigerant and then reload it by weight so as not to err. any advice?
Clima Bueno
Clima Bueno
3.681
hace 5 años
hace 5 años
In what state did you load the 410? Overheating must be between 4 ° and 7 ° and consumption and thermal jump must be controlled. Cheers
Lisandro Raffin
hace 5 años

The consumption is 4.8 A
And the refrigerant charges it in liquid phase

Responder
Lisandro Raffin
hace 5 años

And the thermal jump is 24 ° above and at the output of the turbine 14 °

Responder
Clima Bueno
Clima Bueno
3.681
hace 5 años

The thermal jump is low, the consumption high, take out refrigerant. Cheers

Responder
Lisandro Raffin
hace 5 años

How can I remove some refrigerant? I do it in low with the equipment in march? Thank you

Responder
Clima Bueno
Clima Bueno
3.681
hace 5 años

And, another one doesn't fit you.

Responder
Lisandro Raffin
hace 5 años

Give many thanks !!

Responder
TRIATLON99
TRIATLON99
6.267
hace 5 años
hace 5 años
Hi, it is past refrigerant with that maximum 125 psi temperature, you have to take out refrigerant and control. Are the units clean? Capacitors? Tension? Is the equipment cold? What plate did you place?
Lisandro Raffin
hace 5 años

Hi, it's cold heat, I did maintenance, voltage 220v
Place universal plate qd-u08pgc +

Responder
TRIATLON99
TRIATLON99
6.267
hace 5 años

Is the original plate with hall sensor? Upload a photo of the platelet connection diagram.

Responder
Lisandro Raffin
hace 5 años

Yes, the original is with Hall sensor. It has the turbine 6 cables. In a connection 3 (red black and white) the other connection (yellow red brown)

Responder
TRIATLON99
TRIATLON99
6.267
hace 5 años

Photo of the single plate plate you used?

Responder
TRIATLON99
TRIATLON99
6.267
hace 5 años

Is the new one that comes with displey, how did the external fan that does not cut?

Responder
Lisandro Raffin
hace 5 años

I connected it where it says Out fan on the plate, that is to say cut the compressor but not the outside fan
And since the device is turned on, E3 appears on the display

Responder
TRIATLON99
TRIATLON99
6.267
hace 5 años

Did you check the inside fan connection? placed the hall sensor on the universal plate?

Responder
Lisandro Raffin
hace 5 años

If you place the Hall sensor on the plate
The indoor fan runs ten

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.93
(14)

Curso Reparación de Equipos de Audio de Alta Fidelidad

Maximiliano Resch
$ 60 USD
$ 20 USD
4.25
(8)

Reparación de Placa Main TV LED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 40 USD
$ 20 USD
4.71
(7)

Curso TV OLED y QLED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 29 USD
$ 10 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis