Air conditioner

Does not cool air conditioning

.hugo
.hugo
22
hace 5 años
hace 5 años
That such friends put an air 20 days ago the client called me that did not cool verifico if he has gas connecting the manifester and had what weirdly note is that he did not start the motorcycle. The installation of the pipe is 8mtr does not inflate something in the distance that may have happened since a lot of grace
VICEREFRI
VICEREFRI
1.092
hace 5 años

regards!! hugo for what you say you should check the compressor disconnect and measure it between pins to see if there is continuity? among all to rule out that the coil is open, and the capacitor measures the capacitance to discard also, in what you comment about the pipe by the distance you must start the compressor unless it is clogged or bent and does not allow the refrigerant pass and the motor-compressor is protected internally by thermal and does not start good luck friend .....

Responder
omorma
omorma
15.708
hace 5 años
hace 5 años
Hello, how are you? If the compressor does not start and does not emit any noise, a cable from the terminal block of the outdoor unit or loose can be loose or also in the compressor terminal block have a loose or loose card, the capacitor has been damaged, try to start it directly from the terminal of the compressor to rule out that it works correctly and then continue with the plate relay, greetings.
Chuca
Chuca
394
hace 5 años
hace 5 años
Hello partner, the equipment usually comes with enough gas for an installation of about 6 meters, check that there is probably a lack of gas, comment that such was a greeting, like and accept a solution
.hugo
.hugo
22
hace 5 años

What a friend gas has but does not start the tension compressor arrives because of the outdoor unit forsador

Responder
Rafa 2018
Rafa 2018
535
hace 5 años
hace 5 años
How about that question, however much you lack coolant, the compressor should start
Juan Carlos Rivera
hace 5 años
hace 5 años
You should get a multimeter to measure if the voltage reaches the compressor and measure the compressor bibinate, the cables may be loose, it could be sulphated. Maybe the capacitor. The compressor can be connected directly to the voltage to see if it starts. Luck
Gary1
Gary1
20
hace 5 años
hace 5 años
Hello Friend . If what does not start is the compressor. First unplug or cut the thermal. If it starts without problems, it is possible that it lacks gas. if the problem persists check the arrival of the lines to the comp. According to the item, check the capacitor, the thermal, the line connection, making sure you have a good contact
TTT
TTT
TTT
41
hace 5 años
hace 5 años
Hello, what tension are you measuring, is it cold alone or cold heat? If it is cold heat, does the indoor unit send tension to the compressor?
carlos8612
hace 5 años
hace 5 años
The first thing to do is measure if the capacitor is reaching voltage if it is 110V or 220V, it should reach the terminal of the unit, in fact if the voltage reaches the terminal it should also turn on the fan. If you do not turn on the fan or the compressor, it is because there is no voltage coming to the unit. If you only turn on the fan, the problem is in the compressor, then the capacitor should be measured, if it is well, measure the thermal to check if it is open or connect the compressor directly without the thermal to discard it.
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.93
(14)

Curso Reparación de Equipos de Audio de Alta Fidelidad

Maximiliano Resch
$ 60 USD
$ 20 USD
4.6
(10)

Curso Localización de Fallas en Refrigeración en Heladeras/Neveras On/Off

Yamil Alarcón
$ 29 USD
$ 12 USD
4.87
(15)

Curso Diseño de Amplificadores de Máxima Fidelidad

Maximiliano Resch
$ 29 USD
$ 13 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis