Air conditioner

The pipe is frozen high in air cond. split

Dr. electron
hace 5 años
hace 5 años
I have a split air that was repaired by a colleague for a leak in the low pipe by cracking the flange. Now the air freezes in the high pipe and the low pressure in 10Psi. I have two assumptions, 1) refrigerant leak 2) clogged capillary. what dou you recommend?
Ricardo Ab.
Ricardo Ab.
5.181
hace 5 años

To size

Responder
alpablape
alpablape
102
hace 5 años

It is very important to try if you have the equipment to test with nitrogen, in particular I leave it at least from one day to another and if it does not lower the needle I proceed to the rest that guarantees a good job as well as saving time and money, it is only an opinion!

Responder
Dr. electron
hace 5 años

Here nitrogen is very expensive. We use 300 psi air and soapy water to detect leaks. Then a good vacuum. And ready gas was charged. After finishing, I turn off the unit and with the same equilibrium pressure it is verified that there is no leakage with soapy water.

Responder
apiconauta
apiconauta
3.917
hace 5 años
hace 5 años
Hello Dr. Elctron: If you can take out the covers and see it in operation you can get to realize if the filter or capillary is covered, it also verifies the consumption that also guides you in the possible cause of the problem. From the moment it starts you have that low pressure? I assume that the condenser has already been cleaned and the correct operation of the condenser forger and its capacitor has been verified. This is the option without spending anything on materials. The other is to add some refrigerant and see how it reacts, without adding and the pressure does not rise, well it can already be a partial obstruction of the filter or capillary. Luck, comment your results.
Dr. electron
hace 5 años

The forcers work normal. The idea of consumption is good. Assuming that I have a high consumption problem should be obstruction. And if the consumption is low it must be leak. I will do that, thanks apiconaut.

Responder
Dr. electron
hace 5 años

Hello friend, I already solved, indeed the consumption was low, in the case of a split air of 12000btu / h and 220 volts, the normal consumption is 5.7 A according to the plate. And in the measurement it gave me 2 A. So I looked for the leak and found it at the high junction. Thank you.

Responder
apiconauta
apiconauta
3.917
hace 5 años

Ok partner I'm glad you solved the problem. Luck and at your disposal.

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.93
(14)

Curso Reparación de Equipos de Audio de Alta Fidelidad

Maximiliano Resch
$ 60 USD
$ 20 USD
4.84
(25)

Curso Práctico de Reparación y Bobinado de Motores Eléctricos

Héctor Castiñeira
$ 60 USD
$ 20 USD
4.94
(16)

Curso Refrigeración Comercial Aplicado a Diagnóstico y Reparación

Ing. Georga Melgarejo
$ 40 USD
$ 13 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis