Hello everyone, I commented that I did check the plate and the conclusion is that the integrated clearing is a plate with a very complicated connection since the turbine motor has phase and neutral and 2 ace wires of the capacitor but we do not know where it gets the neutral because to activate the two relays the two are connected to positive so it is a mystery for me and for those who check it another thing that made the plate is that I reversed the output of the inverting valve limes and bone external fan I have two wires one positive black to a reversing valve and a red one to an external fan.
because when starting in cold mode I gave black valve current to the valve and not to the outside fan and there was no way to change that problem, so that the plate went crazy. Well then, to this solution, I bought a universal relay plate with three speeds, I connected it and it is already working perfectly and everything works properly, so thanks for your help I want to clarify that I did not make it react because the integrated ones are not achieved
Hi, no, it's not a problem of a weak prisoner in a hurry, I misunderstood and gives rise to doubts. I meant that testing the direct motor at 220v works, but if I connect to the board, it doesn't work, so it's a board issue from and