Air conditioner

TOP HOUSE brand air conditioner Model THSC65WCP does not cool

Tritóntecnico
hace 5 años
hace 5 años
When installed and proceed to corroborate its operation, the indoor unit turns on, the indoor fan works but only throws wind at room temperature. the outdoor fan also but only works for 3 or 5 minutes and turns off, pulls wind, the temperature of the pipes that connect to the bearings are at room temperature. the manifould marks 250PSI low and does not vary with the equipment on or off. I think the terminal connections are fine but today I will check again. Any suggestions? I would greatly appreciate your collaboration and suggestions. I think that because of the way the pressure manifests and the temperature of the pipes, the compressor would not be working because it would have to go down for at least an instant when it sucks. Unfortunately, the person who was above verifying its operation did not know how to tell me. But I went ahead to ask if this happens normally and the inconvenience may be another. Thank you very much for understanding.
Aregasplo Instalación Rep
hace 5 años
hace 5 años
Hi, are the valves open?
Tritóntecnico
hace 5 años

Yes, the valves are open, sorry for not clarifying it.

Responder
pablo lamas
pablo lamas
2.661
hace 5 años
hace 5 años
Hello partner, you must check if the compressor works and measure your consumption, regards.
Tritóntecnico
hace 5 años
hace 5 años
Hello good morning colleagues! Ready! I already found the inconvenience. As I was guided by the connections proposed in the manual, I realized by comparing with the electrical diagram circuits provided by the manufacturer, which differed in the number of connection terminals that they indicated were correct. The manual did not take into account the terminal indicated with No. 5 as it indicated not to connect. but if I checked the circuit that is printed on the indoor unit as the outdoor unit, terminal 5 corresponded to the contact of the outdoor unit or condenser and fed directly to the compressor. Thank you very much to all who collaborated. Although I will have to check the connections of the pipes since the liquid pipe is frozen and the low pressure operating in cold mode is 55 PSI for R410a. Which indicates a possible lack of refrigerant. But anyway, that's another story. Thanks again.
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.84
(25)

Curso Práctico de Reparación y Bobinado de Motores Eléctricos

Héctor Castiñeira
$ 60 USD
$ 20 USD
4.87
(15)

Curso Diseño de Amplificadores de Máxima Fidelidad

Maximiliano Resch
$ 29 USD
$ 13 USD
4.64
(11)

Curso Electrónica para Reparación de Placas

Santiago Cediel
$ 29 USD
$ 11 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis