Air conditioner

Freezes freezes low spout

Juan Manuel Piccoli
hace 5 años
hace 5 años
Hello good afternoon. I explain my problem, several weeks ago I noticed that the low spout was freezing even froze in the indoor unit. Check the filters and they were a bit dirty, clean them and stopped doing it for a few days and then came back. I gave the pressure and had 120psi in low bone that gas is not. If I noticed that when the air that pulls the indoor unit is also frozen, it is not constant as it lowers and increases the intensity. Now I consult. What could it be??? it might not have made him empty ??? I was not at the facility but I think they did not, last year it worked well. the other option I think is that last year the outdoor unit was under a half shadow and now we made a roof and there was little space between them. I hope your help thanks! Sanyo 3500 air only cold gas r410a
Hernan cardozo1
hace 5 años
hace 5 años
Hello, the same thing happened to me and I found the dirty turbine, full of dust ..... I cleaned it and it started working properly
Juan Manuel Piccoli
hace 5 años

Do I have to disarm the entire front or lower the equipment?

Responder
Geko
Geko
591
hace 5 años
hace 5 años
Lack of maintenance in indoor unit!
Gregorio829
hace 5 años
hace 5 años
Hello friend .. it may be moisture bound with gas If the unit was minted recently, it may be that it has internally seized moisture.
José-Misiones
hace 5 años
hace 5 años
Hi, it could be a low performance turbine of the indoor unit, it is usually because of the undervalued capacitor. I would have to check it and / or change it Regards
Juan Manuel Piccoli
hace 5 años

Is there any way to test the train?

Responder
José-Misiones
hace 5 años

Yes, it is tested with a capacimeter (some tester / clamp amperometric usually bring this option, but not all). If you do not have this tool, you can choose to change it directly, since it is a relatively inexpensive replacement. There are teams that bring it mounted on the board and others separate from it. To access the housing of the indoor unit must be removed.
But, first of all, it would be good for the turbine to be cleaned properly as suggested by other users (I have already done that it had already cleaned everything), because if the turbine has accumulated a lot of fluff it does not blow well

Responder
germancuff1978
hace 5 años
hace 5 años
Doing a good cleaning to the deep indoor unit changes the capacitor. That is almost certainly what you say it does. And since you're cleaning the condenser well.
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.25
(8)

Reparación de Placa Main TV LED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 40 USD
$ 20 USD
4.64
(11)

Curso Electrónica para Reparación de Placas

Santiago Cediel
$ 29 USD
$ 11 USD
4.64
(45)

Curso Tecnología Inverter - Fabricación de probadores y herramientas

Yamil Alarcón
$ 240 USD
$ 40 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis