Air conditioner

Evacuate R410A, how to do it?

morel
morel
2
hace 5 años
hace 5 años
Hello YOREPARO, My BGH OF 3000 Lost pressure for a flare nut and I have to recharge, the question is how to evacuate the refrigerant from the equipment, special equipment is needed or is there any practical way to make it more homemade? If it is possible to answer my question, what would be the pressure to realize how much fluid remains more or less, I may not have to evacuate the R410A and just have to complete the load, this equipment carries 560 grams. I hope not to be so complicated from now thank you very much Sergio Morel
alxxx
alxxx
45
hace 5 años
hace 5 años
Release the remaining gas or use a collector to remove it from the system You have to repair the leak. Perform 20 minutes of vacuum Enter the amount of refrigerant needed in this case 560 grams eye ... must be in the LIQUID phase .... the pressure should be 120 psi aprx
alxxx
alxxx
45
hace 5 años

It is not necessary to use nitrogen for that you enhance the system

Responder
lenin_jesus
lenin_jesus
5.034
hace 5 años
hace 5 años
Hello how are you? Once the R410A has leaked or lost, the ideal thing is to remove everything from the system and reload it. The R410A is a mixture so it must be charged in liquid phase, the working pressure is 110psi to 120psi at a temperature of 25 ° C. The ideal way to evacuate what is left of the refrigerant in the system is to recover it in a disposable bottle, although there are people who dispose of it in the environment, it all depends on the rules of your country. remember that before recharging it again make a good vacuum to the system and load it in liquid phase greetings
morel
morel
2
hace 5 años

Very clear all amogos, but the rest stagnant I push it with nitro?

Responder
yesidrefriaaa
hace 5 años
hace 5 años
WHAT THE SCHOOLS SAY IS THE NORMAL PROCEDURE, IF YOU CONNECT HOW THE VACUUM PUMP MUST BE ADAPTED TO THE MANOMETER FOR A PRUDENT TIME (IF YOU DON'T KNOW WELL BETTER DO NOT DO IT) YOU WILL REMOVE ALL THE REFRIGERANT THAT IS REQUIRED AND RETURN TO LOAD THE EQUIPMENT IN NORMAL PARAMETERS

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.25
(8)

Reparación de Placa Main TV LED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 40 USD
$ 20 USD
4.6
(10)

Curso Localización de Fallas en Refrigeración en Heladeras/Neveras On/Off

Yamil Alarcón
$ 29 USD
$ 12 USD
4.64
(11)

Curso Electrónica para Reparación de Placas

Santiago Cediel
$ 29 USD
$ 11 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis