Air conditioner

air turns off by thermal

orcas411983
hace 5 años
hace 5 años
Hi, I'm talking to you because I don't know if I can take the heat from my air conditioner. I have already done everything I can check the gas pressures. change capacitor for a bigger one since my air conditioner is 110v and I put 50mf capacitor to make the boot more effective I exchanged the thermal for another believing that this would solve nothing helped me, the only thing I notice is that the compressor gets too hot, I don't know because if everything works well structurally apart, place a starkit condenser to see if that helps and nothing covered is not or did not differentiate it with the naked eye because the pipe cools and the compressor works the moment it starts very well it really compresses the only thing I see is to remove the thermal and run the risk that it explodes due to overheating tell me that I still have to do it lower the gas pressure several times and I returned it to put in its normal and equal capacity the same inconvenience The compressor is an LG from 12000btu at 115volts
TRIATLON99
TRIATLON99
6.267
hace 5 años

Hello, do I control the external forcer? Consumption voltage?
What consumption is on the label?

Responder
eduardo otero
hace 5 años

the capacitor has to be of the same power as it had, a bigger one would harm, do not put it without heat, you can burn the motor compressor, try the forger separately, and the motor compressor, take the amperage and see that it matches what it marks the manufacturer, luck

Responder
TRIATLON99
TRIATLON99
6.267
hace 5 años

Line tension?

Responder
TRIATLON99
TRIATLON99
6.267
hace 5 años

Missing data to approach the diagnosis are all assumptions, tension, working pressure ......

Responder
abel reyes
hace 5 años
hace 5 años
Hello first you should check if the condenser is clean if the fan is spinning well then check that consumption in amper has for 110v 12000btu should be close to 11 amper the thermal should not be removed
orcas411983
hace 5 años

If the condenser is new, the air will be serviced before the fault, its maximum consumption amperage when switched on is 10.57 amps, as soon as it matches its consumption, it is between 9 and 10 amps

Responder
Mimol92
Mimol92
8.033
hace 5 años
hace 5 años
Good afternoon, the consumption is within the range to be a 110V compressor, it seems that you are not firing by consumption but by temperature, it is likely that the compressor is lacking in oil and therefore it gets too hot; also that excessive heat may be due to the fact that the compressor has compression problems in its internal structure and is returning hot gas, that is, it is decompressing, if so, you will notice that the manometer needle does not remain fixed, but goes up and low.
orcas411983
hace 5 años

thanks mimol92 I knew that something was left to do was the oil a while ago the capillary had broken and it had to be changed but the truth oil that has logic is not complete your answer I'm going to get to solve that make it serve to the compressor to change all the grateful oil really here in Venezuela things are too expensive with that answer you helped me a lot

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.25
(8)

Reparación de Placa Main TV LED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 40 USD
$ 20 USD
4.6
(10)

Curso Localización de Fallas en Refrigeración en Heladeras/Neveras On/Off

Yamil Alarcón
$ 29 USD
$ 12 USD
4.64
(11)

Curso Electrónica para Reparación de Placas

Santiago Cediel
$ 29 USD
$ 11 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis