Window Air Conditioner LG, 12 THOUSAND BTU IS VERY FOLLOWED

luigi brito
hace 6 años
hace 6 años
The Air stops very often giving no time to cool, it lasts five minutes working the compressor and rests 5 minutes working the fan and starts and so on, They know why this is happening, the thermostat knob is at maximum and still , do the same,. Thank you please ...
Mimol92
Mimol92
8.033
hace 6 años
hace 6 años
Good evening, it can be two things, the first is that the thermostat is defective by sending the compressor on and off very often, if the compressor when it turns off does not reach voltage, then it is the thermostat, the second is that the thermal protector of the compressor for high consumption, if you check when the compressor is turned off and verify and voltage is coming, then it is definitely because of the thermal protector of the compressor that is stopping and this can be due to many causes: Capacitor damaged or deficient, contacts loose or sulphated electrical, dirty rear honeycomb, excess refrigerant, plugging in the capillary tubes, unstable and out of range voltage (voltage), superheated compressor electric coils, etc.
luigi brito
hace 6 años

hello, thanks, .. it was maintenance and it works perfect ,.

Responder
Mimol92
Mimol92
8.033
hace 6 años

Perfect, I'm glad you solved the problem, we are here to serve you, regards.

Responder
friovega63
friovega63
11.849
hace 6 años
hace 6 años
Hi Luigi, In addition to what the colleague recommends before. You must first verify that the thermostat bulb never fully hits the evaporator panel. Second check the cleanliness of the air filter in the front mask of the conditioner. Third clean with a brush, any accumulated dirt, which may be making contact between the thermostat bulb or temperature control and the evaporator front panel, if necessary, preferably perform a general maintenance of the equipment. S @ lu2 friovega63.
luigi brito
hace 6 años

Thank you. After doing maintenance it works perfect.

Responder
friovega63
friovega63
11.849
hace 6 años

Hi Luigi, thanks to you for the communication, here we wait to help you. S @ lu2 friovega63.

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.84
(25)

Curso Práctico de Reparación y Bobinado de Motores Eléctricos

Héctor Castiñeira
$ 60 USD
$ 20 USD
4.25
(8)

Reparación de Placa Main TV LED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 40 USD
$ 20 USD
4.71
(7)

Curso TV OLED y QLED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 29 USD
$ 10 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis