I have a Samsumg 220v AW12P0BC 12000BTU Window Air at the same the capacitor was removed and I want to repair it since the compressor is damaged but I don't know what capacitor is used and I want to buy it if someone can help me with the model and characteristics of the capacitor that is required to this air Thanks P_20180405_103423.jpg [1.33MB] P_20180405_103329.jpg [994.61kb]
carlos8612
hace 6 años

Good afternoon, place one between 30 and 35 470v microfarads with that works well for you

Responder
carlos8612
hace 6 años

Good afternoon, place one between 30 and 35 470v microfarads with that works well for you

Responder
carlos8612
hace 6 años

Good afternoon, place one between 30 and 35 470v microfarads with that works well for you

Responder
friovega63
friovega63
11.849
hace 6 años
hace 6 años
Hi Tecluna, your air model basically, uses a capacitor of 30 microfarads, for the compressor and one of 3.5 microfarads, also for the fan, both at 450 volts of 60Hz alternating current. I clarify the term basically, because Samsung depending on the geographical area or country, manufactures similar models, but at the same time differ from each other, for example in capacitors that use higher capacity such as 35mf for the compressor and those of 4 microfarads for the fan, or these may be combined with each other into a single common that is then subdivided, or each independent, even in the case of the same compressor motor and the same fan or fan motor. Reason why, if you intend to replace the compressor of your equipment, because it says it is damaged. As a precaution, I suggest that you better wait, see what offers the suppliers have in the market in your area, since they usually sell their products with the included capacitor. If anticipated, it would run the risk of losing the warranty in case of problems with the new compressor, if they find an incorrect capacitor, or not supplied by them. In addition, they might not have compressors of that brand and need to buy a substitute, from another manufacturer to solve the problem. S @ lu2 friovega63.
TRIATLON99
TRIATLON99
6.267
hace 6 años

In equipment of 300kcal or 12000 btu, for the maximum forcer 2.5 uf.

Responder
omorma
omorma
15.708
hace 6 años
hace 6 años
Hello how are you, with one of 30 uf x 400v works greetings.
carlos8612
hace 6 años
hace 6 años
Good afternoon, place one between 30 and 35 470v microfarads with that works well for you
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.84
(25)

Curso Práctico de Reparación y Bobinado de Motores Eléctricos

Héctor Castiñeira
$ 60 USD
$ 20 USD
4.25
(8)

Reparación de Placa Main TV LED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 40 USD
$ 20 USD
4.71
(7)

Curso TV OLED y QLED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 29 USD
$ 10 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis