⚡ Descuentos en cursos en video - Lleva tu aprendizaje técnico al siguiente nivel y aprovecha precios especiales antes de que termine la oferta. 🔥 Aprovechar oferta ahora 🔥
Air conditioner

Samsung aw12pkac air compressor does not fit

Jorge Patricio Nolasco
hace 6 años
hace 6 años
Good evening. My weather had a lot of dirt in the coil, I washed it and then turning it on it no longer cools, only the fan works but the compressor does not enter only a very slight crass, after a while the fan slows down and then re-enters. Already check capacitors and are well, the compressor has continuity in its tips is not grounded. What could be the problem. (Samsum aw12pkac)
duglas
duglas
1.680
hace 6 años

Which unit did you clean both or only one and which one was.

Responder
Jorge Patricio Nolasco
hace 6 años

Both

Responder
duglas
duglas
1.680
hace 6 años

Verify that 220v reaches the compressor when you want to enter

Responder
Jorge Patricio Nolasco
hace 6 años

I'm not technical but I know something. Just confirm me that Czech voltage that voltage

Responder
Jorge Patricio Nolasco
hace 6 años

Nothing reaches the compressor terminals

Responder
Jorge Patricio Nolasco
hace 6 años

But the compressor gets very hot

Responder
duglas
duglas
1.680
hace 6 años

If it heats up, it is because if terminal voltages arrive, you tell me that if one of two tries to start the compressor is locked or it is the faulty capacitor

Responder
duglas
duglas
1.680
hace 6 años

When the compressor is locked and the internal thermal of the compressor is overheated it will open and when it cools it will try to start again and again for the sake of safety the thermal

Responder
Jorge Patricio Nolasco
hace 6 años

Check the capacitor and and measure the 50 microphones, there is continuity in the RS RC CS compressor terminals and none is grounded. Even so the compressor may be locked? If so, what would be a solution?

Responder
duglas
duglas
1.680
hace 6 años

It is not necessary that it is burned or landed, you can try it directly for a moment and check if it is really locked

Responder
Jorge Patricio Nolasco
hace 6 años

Ok thanks for your help

Responder
Jorge Patricio Nolasco
hace 6 años

I tried it in a direct way and what it does is an assumption like wanting to come in and after a moment it sounds like something opens inside. (pouf) and if I leave it repeat the same and get hot.

Responder
duglas
duglas
1.680
hace 6 años

You took the consumption in the test you put direct voltage with a new capacitor but in any case if the test is with new and direct capacitor it is logical that the compressor is locked and you will have to replace it is a shame is the worst thing that can happen to a split

Responder
Jorge Patricio Nolasco
hace 6 años

Ok thanks duglas for your great help.

Responder
duglas
duglas
1.680
hace 6 años
hace 6 años
You took the consumption in the test you put direct voltage with a new capacitor but in any case if the test is with new and direct capacitor it is logical that the compressor is locked and you will have to replace it is a shame is the worst thing that can happen to a split Greetings colleague.

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.93
(14)

Curso Reparación de Equipos de Audio de Alta Fidelidad

Maximiliano Resch
$ 60 USD
$ 20 USD
4.6
(10)

Curso Localización de Fallas en Refrigeración en Heladeras/Neveras On/Off

Yamil Alarcón
$ 29 USD
$ 12 USD
4.87
(15)

Curso Diseño de Amplificadores de Máxima Fidelidad

Maximiliano Resch
$ 29 USD
$ 13 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis