Hello, what is required by the warranty on equipment with r 410 a is three meters.
From 2 meters of pipe work very well, the important thing is to control the pressure after 15 'of walking, in both modes.
With r 22 from 1.5 meters.
Regards
Hello, what is required by the warranty on equipment with r 410 a is three meters.
From 2 meters of pipe work very well, the important thing is to control the pressure after 15 'of walking, in both modes.
With r 22 from 1.5 meters.
Regards
Hello duglas, allow me to disagree to avoid confusion. According to the manual of the equipment, they have a minimum and a maximum, although as omorma points out, it is between three (minimum) and five (maximum) after which you have to add refrigerant per added meter you cannot put twenty meters of pipe and not only that It also depends on whether the distance is horizontal or vertical. Clarified that I will add that depending on the distance you have to change the diameter of the pipe and it will be seen if oil retention roller is needed. Well in short the thing is not so simple, you have to know.