18000w air problems cold three-phase heat

jose alberto brombin
hace 6 años
hace 6 años
hello to the forum I have problems with an air ROOF TYPE of 18000 w cold heat philco brand three-phase mod: PHP TH3617NE GAS 410A: Cold works well but in heat when it starts at high pressure it goes to 700lbs and cuts the pressure switch high and hard A few minutes in progress and stops and starts again. We change the reversing valve. It worked well 20 minutes and when we stopped to rearm all the equipment when put it into operation again. He did the same problem again, someone can help me discover it. Thank you.
TRIATLON99
TRIATLON99
6.267
hace 6 años

Hello that team does the expansion in the evaporator, will it not be covered?

Responder
jose alberto brombin
hace 6 años

hello the team is new I thought it was a reversing valve because when I connect high and low and turn it on heat the two pressures go very high and cut by high. but cold works well if I have 90 pounds low and 110 high. I thought that inv valve: it was locked in the middle but it works well with the tests on the valve. and in a moment it worked well and when we turned it on again it no longer. What I also noticed is that the evaporator inside the forcer starts when the pressure is reaching 600 pounds. and cuts high and the forcer starts working.

Responder
Gabrielrefrigeracion84
hace 6 años

What gas does it carry?

Responder
Gabrielrefrigeracion84
hace 6 años

In the high when it is cold you have to have about 400lbs of pressure

Responder
Gabrielrefrigeracion84
hace 6 años

What room temperature is there?

Responder
jose alberto brombin
hace 6 años

hi guys thanks for the replies. the gas is 410 and room temperature is 18 ° C. But I already solved the problem. I comment:
I changed the reversing valve and when I checked I found a small orange plastic chip oblivious to all the tools that are normally used in the installation after giving it a few strokes, a slightly smaller one appeared, but not in the form of a chip but solid as a millimeter of diameter of the same color replace the valve I blew it and welded a new one and it was in perfect condition with a low pressure of 110 pounds and high 425 lib.

Responder
jose alberto brombin
hace 6 años

Thank you very much and I appreciate the answers and count on me for any solution that we can provide. Thank you. Thank you that you are still in the forum. It is a great help for everyone.

Responder
Gabrielrefrigeracion84
hace 6 años
hace 6 años
Be sure to rate the answers and what was the answer that helped you solve your problem
jose alberto brombin
hace 6 años

in reality all the answers formed data to be able to arrive at the problem I value all the comments were all very useful.

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.84
(25)

Curso Práctico de Reparación y Bobinado de Motores Eléctricos

Héctor Castiñeira
$ 60 USD
$ 20 USD
4.25
(8)