Hello good night in advance I appreciate your attention. I have a mini split equipment brand mabe which install since again uses ga 410 to the case is that it only lasted a week and I stop cooling surely there is a leak then recharge a can of 410a which is the equivalent ah 650 g the same as it indicated to me in the data sheet that is added to the condensing unit but it still did not cool and the discharge tube was completely frozen, so I decided to turn off the equipment. The questions are why did the tube freeze? in the manometer I mark 50psi If the tube is new, the leak is probably in the conical nuts. Is there any type of sealant for these nuts? and finally I have read that the gas 410a is recharged in liquid face with the equipment off and after charging wait 15 to 30 min. to start up or what is the correct way to make the gas charge 410a I hope you can help me thank you all for your time and contributions.
omorma
omorma
15.708
hace 6 años
hace 6 años
Hello how are you, this is the correct way to load and manipulate the R410 greetings. https://yoreparo.com/refrigeracion/aire-acondicionado/manuales/5828501/procedimiento-de-carga-r-410a
Isaby Catalan Bustamante
hace 6 años
hace 6 años
Did you empty when you did the installation? if injected in liquid phase with the equipment on. try putting soap on the pipe joints, do not use Teflon on the nuts. and if it is refrigerant 410, the pressure is not 60 psi, it is 115 psi in the same low the first time it did not cool because it lacked refrigerant and in the second one because you passed gas.
ubaldo martinez
hace 6 años

I did the vacuum when I installed it the first time 40 min. and then there will be the high and low keys when I realized that it does not cool connect the pressure gauge and it only marked me 10 psi I thought that it would only be necessary to tighten the nuts and bolver to load gas but I realized that it began to freeze the line of high forget to mention that it is 12000 btu and the pipes did not increase with which it brought alknso

Responder
Isaby Catalan Bustamante
hace 6 años

Ok, if I understood
When you checked that it did not cool and was frozen, did you put your air in ventilation mode so that it defrosted or so frozen, did you check pressures? If so, you must wait for it to thaw and then check pressures. And if you checked pressures already defrosted the equipment and it gave you 10 psi you should have leak check the connections with soap maybe you squeezed too much and damaged the countersink

Responder
Vlack22
Vlack22
140
hace 6 años
hace 6 años
Good friend .. First, if there is a leak, it is the safest. Before loading the gas you would have to make the vacuum. Then load the gas in liquid form with diffuser valve. The gas 410 is a mixture of gases that is why it is charged in a liquid way so the gases enter evenly. you can look for the leak with a mixture of water and some detergent .. The load is made of apoco. Not all at once .. Luck
ubaldo martinez
hace 6 años

ok boy understanding i have a question if i can't get nitrogen can i pressurize with r 410 gas in face gas to detect leaks?

Responder
Vlack22
Vlack22
140
hace 6 años

Yes. It can..

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.25
(8)

Reparación de Placa Main TV LED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 40 USD
$ 20 USD
4.6
(10)

Curso Localización de Fallas en Refrigeración en Heladeras/Neveras On/Off

Yamil Alarcón
$ 29 USD
$ 12 USD
4.64
(11)

Curso Electrónica para Reparación de Placas

Santiago Cediel
$ 29 USD
$ 11 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis