⚡ Descuentos en cursos en video - Lleva tu aprendizaje técnico al siguiente nivel y aprovecha precios especiales antes de que termine la oferta. 🔥 Aprovechar oferta ahora 🔥
Air conditioner

Hitachi HSB HI-fI ECO 3200 W compressor connection

MGFerrucci
hace 6 años
hace 6 años
https://adjuntos.yoreparo.com/imagen_post/0004/44/d3f2b07d98e432b8163a6ba15c937e33f80c53d4.jpeg" alt="" /> [img] https://adjuntos.yoreparo.com/imagen_post/0004f44cfaaaaaaaaaaa [/img[[img[https://adjuntos.yoreparo.com/imagen_post/0004/44/ce4390825a6c4318ec2188981099ac739dd10485.jpeg[/img[Good evening, I have a Hitachi HSB HI-FI ECO 3200W air conditioner. Recently we installed it with a friend but when connecting the indoor unit to the compressor we noticed that the colors of the cables do not match those described in the indications of the compressor. I enclose images of the 5 cables that come out of the split and the terminal block in the compressor. Will you have any idea if this is a "Standard or how can I know where to connect them? From already thank you very much. Regards
TRIATLON99
TRIATLON99
6.267
hace 6 años

Hello, what you have to know is which is neutral, compressor, forcer and investor in the interior.

Responder
MGFerrucci
hace 6 años

Thanks for answering!

Responder
filotop
filotop
411
hace 6 años
hace 6 años
Hello MGFerrucci, you put brown in 1, black in 2, white in 3, blue in N and green in the chassis, then you go to the internal unit and look for the electrical diagram of this one and brown in compressor, black in fan, white reverse valve, blue in Neutral and green to the chassis ... Send the photo of the evaporator diagram in case you have any doubts. . when you go on first you open the gas valves, the small one first. . .comment to continue explaining.
MGFerrucci
hace 6 años

Thanks for answering!

Responder
Pipo1978
Pipo1978
115
hace 6 años
hace 6 años
You have to follow the same connection in UI as in the EU. ALWAYS KEEP NEUTRAL. and everything will be fine. Best regards
MGFerrucci
hace 6 años

Thanks for answering!

Responder
Geko
Geko
591
hace 6 años
hace 6 años
Hello, colors are not important if you connect them in the 2 units in the same way.
MGFerrucci
hace 6 años

Thanks for answering!

Responder
elektomaq
elektomaq
62.202
hace 6 años
hace 6 años
Hello let's clarify a couple of points colors are important but define the connection the connection is defined by the nomenclatures of the terminals, in this way it must be connected 1 with 1 2 with 2 3 with 3 N with 4 (N) earth with earth missing photo of the terminal block of the indoor unit to see the nomenclatures and confirm that data since N could be in another number Now, it is not allowed by electrotechnical regulations to place any color anywhere, two colors must be respected (Mandatory) blue for neutral green for ground (chassis) the rest of the 3 colors are indistinct The compressor is not the whole outdoor unit, it is only part of it In the photo of the terminal board that you uploaded the compressor corresponds the goods 1 white cable since it is noted that it is of greater section than the rest regards
MGFerrucci
hace 6 años

Thanks for answering!

Responder

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.93
(14)

Curso Reparación de Equipos de Audio de Alta Fidelidad

Maximiliano Resch
$ 60 USD
$ 20 USD
4.6
(10)

Curso Localización de Fallas en Refrigeración en Heladeras/Neveras On/Off

Yamil Alarcón
$ 29 USD
$ 12 USD
4.87
(15)

Curso Diseño de Amplificadores de Máxima Fidelidad

Maximiliano Resch
$ 29 USD
$ 13 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis