Flare nut flare due to thread problem of the suction part.

ROBERTO EDGARDO FERRARI
hace 6 años
hace 6 años
Hello :: I have a Philco brand air conditioner with 410 A refrigerant, it is a hot / cold model of 2850 watts, which I was doing well in heat after a few months of not using it I put it in cold and I realize that it does not cool and the cause is which lost the whole load because the 3/8 nut of the outdoor unit is completely loose because the nut has completely dipped, then I proceed to buy some 3/8 new flare nuts, I try it by hand-tightening and walking, Then I proceed to make the tab and everything ok until I start adjusting, since it releases and loosen again, this I repeated four times with four different new nuts and in all the same thing happens it adjusts by hand but when I start to want to tighten I completely do what I can apparently do the thread of the three-way valve is falsified, what solution do you give me since I do not have a welder to change said service valve, so I turn to you to give me a possible solution in all or else there is no problem, I know that it is a problem that is why I turn to someone who tells me how to proceed and if there is any thread in the market that I can use and that serves to rectify the thread so I solve this big problem or in what way I proceed Waiting for a response soon I say goodbye to you very atte. Roberto Ferrari roberferrari@hotmail.com
fonza
fonza
50
hace 6 años
hace 6 años
There are nuts that are shorter, see if you can get it and try it, otherwise you will have to change the bearing. regards
TRIATLON99
TRIATLON99
6.267
hace 6 años
hace 6 años
Hello, if the thread is in bad condition, you must change the bearing. It occurs to me to be able to make a new thread with a tap and change the nut, I did not do it what I am thinking now.
duglas
duglas
1.680
hace 6 años
hace 6 años
I do not see another solution to your problem than changing the valve if you do some other work undoubtedly for sure you will have more problems you can buy a butane straw and the welding gun are not expensive and that serves you for more jobs in the future.
ROBERTO EDGARDO FERRARI
hace 6 años

Thanks to everyone, I tried the above but the best solution was to buy a valve and borrow a soldering iron; So I made the change and after doing all the steps it was the solution xq two days ago that I did it with the help of another colleague that was the one I took it out and the only problem to change it was that we had to resort to a connector curve so that the valve will not be inverted we verify that there are no leaks with nitrogen; we arm; we connect; nitrogen test of the circuit; vacuum and pump check; We loaded and ready is going very well so far; it was the solution

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.87
(15)

Curso Diseño de Amplificadores de Máxima Fidelidad

Maximiliano Resch
$ 29 USD
$ 13 USD
4.71
(7)

Curso TV OLED y QLED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 29 USD
$ 10 USD
4.64
(45)

Curso Tecnología Inverter - Fabricación de probadores y herramientas

Yamil Alarcón
$ 240 USD
$ 40 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis