Air conditioner

Split bgh silent air r22 turns on cool after a while it changes to aut

ethariel
hace 6 años
hace 6 años
Hello everyone, it is wrong that I turn on the program in cool and after a while it seems to turn off and on but it is automatic. If anyone can help me because it does not appear in the error code. From already very grateful.
Geko
Geko
591
hace 6 años
hace 6 años
Try unplugging the equipment for a while and also take out the batteries to the control and discharge it.
ethariel
hace 6 años

Hi Geko, thanks for your help. It was the first thing I did, the control is new. But I will try it again.

Responder
Geko
Geko
591
hace 6 años

Maybe when it reaches the desired temperature it stays like this until it rises again. Put it on 16th turn it on and try!

Responder
friovega63
friovega63
11.849
hace 6 años
hace 6 años
Hi Ethariel, disassemble the plate and check with a magnifying glass or lipa for any welding failure, especially for the sensor area (IR) that is the one that captures the infrared signal of the remote control, also the contacts and connectors of the sensors Even if you already saw that part but review it again, sometimes the pins create sulphation and do not contact well, use the WD-40 I recommend as a great ally for such cases. The other point to review and not least important is the auxiliary power button or button, which can be fixed on the same electronic board or on a small board that is added to the main board (MAIN) through a connector of several pins and cables that can also create problems of false contact in their welding or sulfate between them and the connector plog. This button in addition to giving problems with the welds to the plate, also creates a sulfate inside or rust product of moisture that causes the team to execute orders during operation, which even having a ghost inside the room would give it. In such a case do not rule out the possibility of changing it, the keypad of an old television board, an old computer chassis with its POWER or RESET button or key, until the (VALE) button of the car alarm can supply you said push button or substitute switch. Well, finally, do not rule out, with the utmost respect for your lady, mother-in-law or child who could carelessly play tricks on you and you like crazy without knowing what to do. Ha Ha Ha Seriously Good luck with the ghost. S @ lu2 friovega63.
ethariel
hace 6 años

Hi frigovega63 thanks for helping. The first thing I did was what Geko commented. The control is new and original. I removed the plate from the indoor unit and found black dust, and cleaned it with alcohol, it remained the same. I disassembled it again and found that the base of the tube sensor card was loose, I reinforced the welding to that and other components and chips. And he walked 2 hours later the same fault began. It may be that some of the sensors do not work well. Although I measure resistance and they both don't matter to me ...

Responder
friovega63
friovega63
11.849
hace 6 años

Hi Ethariel, please read my new solution proposal. Thank you. friovega63

Responder
ethariel
hace 6 años

Thanks friovega63 for continuing to collaborate. The power button does not work. That is, I tried the multimeter in continuity and closed the contact but when I tried to turn it on it did not turn on the equipment. I will do what you advise after comment. Million of thanks.

Responder
friovega63
friovega63
11.849
hace 6 años

Hi Ethariel, this push button may not be the cause, but when they take internal sulfate due to the humidity to which these micrites are exposed, which nobody calculates the problems it creates, it is enough that the cover of the split cover or indoor unit is enough Rose a little to go crazy executing operations on your own to the team. So it is not enough to take it into account.

Responder
ethariel
hace 6 años

Hello everyone, I want to thank you and everyone who helped solve my problem. Hi frigovega63 I am indebted to you, because you gave me the solution. The button was the problem, I did a cleaning as you advised me and it didn't fail anymore. Re thousand grateful. Have a nice holiday, hug and blessings for the whole community.

Responder
friovega63
friovega63
11.849
hace 6 años

Hello Ethariel, it is a real satisfaction for the group that you have first solved with our modest help the problem of your air and it rejoices us that at the same time we positively value our commitment to continue cooperating with our Latino community. Thank you for the communication. S @ lu2 friovega63.

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.84
(25)

Curso Práctico de Reparación y Bobinado de Motores Eléctricos

Héctor Castiñeira
$ 60 USD
$ 20 USD
4.87
(15)

Curso Diseño de Amplificadores de Máxima Fidelidad

Maximiliano Resch
$ 29 USD
$ 13 USD
4.64
(11)

Curso Electrónica para Reparación de Placas

Santiago Cediel
$ 29 USD
$ 11 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis