Hello I tell you my situation, I am starting to install air conditioning equipment after having completed a cooling course. Today I went to a friend's home where they told me that they wanted me to charge it with refrigerant gas (R410A) and it was the second time they had loaded it. I told them that this was not normal, that it was convenient to detect the leak and fix it. In the suction bearing I found the loose nut, I assumed that would be the place of the leak, anyway check the rest. I made the load, check the critical points before the possibility of leakage and do not detect anything, the equipment was working with the correct pressure for the temperature of that moment, it cooled well. after 15 min. I noticed that it did not cool the same, I looked again and the pressure came to low completely. This disoriented me What guidance or advice could you give me?
TRIATLON99
TRIATLON99
6.267
hace 6 años

Hello, if you lost the pressure of work mut fast the leak is important.
Both units must be pressurized with nitrogen.
I would start with pipes and evaporator.

Responder
elektomaq
elektomaq
62.202
hace 6 años
hace 6 años
Apart from what the colleague mentions, the r410a always performs full charge, never partial and in liquid phase, if you did so then there is leakage, because of the speed in which you lost the refrigerant can be several critical points A desoldado pipe The distributor in the evaporator The nut you tightened if you just tightened it, you may have swept the tab. If before the pressure was not so low, I lean towards the latter regards
omorma
omorma
15.708
hace 6 años
hace 6 años
Hello, how are you, so that I lose all the refrigerant in 15 minutes the leak should be very large and visible, I estimate that there is a moisture obstruction and this causes the pressure to drop to zero, you should recover the refrigerant and pressurize with nitrogen to look for the leak (because there must be a leak) repair and run nitrogen several times if possible by heating the pipe with heat gun to remove all possible moisture then perform vacuum, keep it for at least 30 minutes and proceed to load with inverted carafe expansion valve by weight then set up controlling consumption pressure and thermal jump greetings.
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.84
(25)

Curso Práctico de Reparación y Bobinado de Motores Eléctricos

Héctor Castiñeira
$ 60 USD
$ 20 USD
4.87
(15)

Curso Diseño de Amplificadores de Máxima Fidelidad

Maximiliano Resch
$ 29 USD
$ 13 USD
4.64
(11)

Curso Electrónica para Reparación de Placas

Santiago Cediel
$ 29 USD
$ 11 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis