⚡ Descuentos en cursos en video - Lleva tu aprendizaje técnico al siguiente nivel y aprovecha precios especiales antes de que termine la oferta. 🔥 Aprovechar oferta ahora 🔥
Air conditioner

Identify Model and Capacitor Air Carrier Split

Edy.ar
Edy.ar
3
hace 6 años
hace 6 años
Furnas Contactor electromagnético.jpg [1.27MB] [url=/ver-adjunto/aHR0cHM6Ly9hZGp1bnRvcy55b3JlcGFyby5jb20vZGVmYXVsdC8wMDA0LzcyL1ZhbHZ1bGFTb2xlbm9pZGUtNTEzOTguanBn] https://adjuntos.yoreparo.com/imagen_post/0004/73/f44fe67302d5e7f2bb340776545c4ddc27f0134b.jpeg" alt="" /> Cables leaving the engine I hope that with this data you can help me From already grateful Contactor Images Regards
NG en linea
NG en linea
9.229
hace 6 años

You are missing the most important data. How many btu?

Responder
Edy.ar
Edy.ar
3
hace 6 años

Online NG: The problem is that all the tag data was deleted
Any help is appreciated.
Regards

Responder
TRIATLON99
TRIATLON99
6.267
hace 6 años
hace 6 años
Hello, yes, LRA is 34, this is divided by 6 and gives you the amperage talking with tensiot of 220 Volt. Daria a little less than 6 Amper, is a team of 3000 refrigerators. Regards
Edy.ar
Edy.ar
3
hace 6 años

Triatlon99: Thanks for the tip, you will have an idea which dual capacitor I need for that team.
Regards

Responder
TRIATLON99
TRIATLON99
6.267
hace 6 años

You say that the external forcer has capacitor, if you need for the compressor 30/35 uf.
If it is dual 2.5 uf / 30/35 uf forger and compressor.
Regards

Responder
Edy.ar
Edy.ar
3
hace 6 años

Triatlon99: Update the question including a diagram of the connections I have
As I connect the three wires to the missing capacitor, they are three loose wires,
two that come from the engine, (Red and White),
and one that comes from the electromagnetic Contactor
Or I am missing something else.

Responder
TRIATLON99
TRIATLON99
6.267
hace 6 años

I can't understand why he has three capacitors.
You must identify common, start and work of the compressor and what their colors are, that is, wires come out of the color compressor.
Comment

Responder
Edy.ar
Edy.ar
3
hace 6 años

Triatlon: I'll check and tell you
Thank you very much for your comments

Responder
Edy.ar
Edy.ar
3
hace 6 años

Triatlon: I comment:
Three wires come out of the compressor
Red with the indication (R)
White with the indication (S)
Black with the indication (C), the latter before leaving makes a bridge with a Thermal Protector (I think)
See images I uploaded

Responder
TRIATLON99
TRIATLON99
6.267
hace 6 años

Red, White go to the capacitor (that red must reach neutral, black is the line of the compressor and goes to the line of the contactor.

Responder
Edy.ar
Edy.ar
3
hace 6 años

Triatlon99: Update with one more image of the situation
You tell me that the RED (R) and WHITE (S) wires go to the capacitor, if it is a common capacitor, with two contacts, I assume that any of the wires goes in any of the contacts.
You also tell me that the RED should arrive Neutral
I have the BLUE wire, which comes out of the Contactor, "Unassigned", is that the one that takes Neutral ???? If so, RED and Neutral (BLUE) are connected to the same Capacitor contact
Confirm me if it is like that
Thank you so much.

Responder
TRIATLON99
TRIATLON99
6.267
hace 6 años

If the red that goes to the capacitor must reach neutral (blue wire).
The blue must not leave the part of the contacts of the contactor, you can take it from the terminal N to the capacitor.

Responder
Edy.ar
Edy.ar
3
hace 6 años

Triatlon99: I told you that the Blue cable is like this, (Do not touch it and it seems original since it is full of dust), and leave the Contactor ????
Could it be that this is wrong?
Below the forero friend Osvaldo Gomez, comments that he takes El Rojo next to Azul, to one of the Capacitor's contacts and Blanco to the other contact, how do you see it?

Responder
TRIATLON99
TRIATLON99
6.267
hace 6 años

Yes it goes where the coil is energized if.

Responder
TRIATLON99
TRIATLON99
6.267
hace 6 años

Upload photos of the contactor.

Responder
Edy.ar
Edy.ar
3
hace 6 años

Triatlon99: I uploaded two images of the Contactor, indicating the cables that come / go from the back and the front, of the latter the cables are directed to the Bornera
THANK YOU

Responder
TRIATLON99
TRIATLON99
6.267
hace 6 años

White and Red to each contact of the capacitor blue wire to the other contact where it is red.

Responder
Edy.ar
Edy.ar
3
hace 6 años

TRIATLON99: THANK YOU.
Very kind in answering my doubts.
I already have to buy the capacitor and try.
Regards

Responder
NG en linea
NG en linea
9.229
hace 6 años
hace 6 años
It carries a capacitor of 35 mf. So you want it dual if the fan has its capacitor. If you want to use only one then look at the mf that has the fan.
Edy.ar
Edy.ar
3
hace 6 años

NG online: I have three loose wires,
two that come from the engine, (Red and White),
and one that comes from the electromagnetic Contactor
that's why I interpret that it is a dual capacitor
Regards

Responder
NG en linea
NG en linea
9.229
hace 6 años

But the capacitor is not connected in the contactor. There goes the cable that feeds your coil so that it excites and closes and - both of the lines.

Responder
Edy.ar
Edy.ar
3
hace 6 años

Online NG: Update the question including a diagram of the connections I have
Could you tell me how the three wires that I have unassigned are connected?

Responder
Edy.ar
Edy.ar
3
hace 6 años

NG online: I comment:
Three wires come out of the compressor
Red with the indication (R)
White with the indication (S)
Black with the indication (C), the latter before leaving makes a bridge with a Thermal Protector (I think)
See images I uploaded

Responder
Osvaldo Gomez Hernandez
hace 6 años
hace 6 años
1.- As the capacitor comments about being 30/35uf, the details are the connection 2.- You have to check the compressor (motor in your diagram): the compressor has three terminals in the shape of a triangle where the black wire is connected is marked with a "C" that is the common one, you should check where they are connected the white and red cables, by deduction I think that the white must be connected in the "R" and the red in the "S" if so you must connect the blue wire and the white wire on one side of the capacitor and the red wire on the other side I hope it is useful Regards
Edy.ar
Edy.ar
3
hace 6 años

Osvaldo Gomez:
The BLACK wire (C), connects to the Contactor,
But the wires are marked differently than what you indicate RED (R), and WHITE, (S), Can It Be ????
I uploaded a new picture of the situation
Thank you

Responder
Osvaldo Gomez Hernandez
hace 6 años

hello if it's ok, you just have to connect the blue wire along with the red one on one side of the capacitor and the white wire on the other side of the capacitor

Responder
Edy.ar
Edy.ar
3
hace 6 años

Osvaldo Gomez: Thank you very much, I already have to buy the capacitor and try
Regards

Responder

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.84
(25)

Curso Práctico de Reparación y Bobinado de Motores Eléctricos

Héctor Castiñeira
$ 60 USD
$ 20 USD
4.25
(8)

Reparación de Placa Main TV LED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 40 USD
$ 20 USD
4.87
(15)

Curso Diseño de Amplificadores de Máxima Fidelidad

Maximiliano Resch
$ 29 USD
$ 13 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis