Air conditioner

The outdoor unit starts directly

Yadian Castañeda Cruz
hace 6 años
hace 6 años
Hi .... The split type air conditioner (LENNOX LM018CO-100P432-1) has a switch that when I turn it on, the outdoor unit starts directly (IT MUST NOT BE ... THIS UNIT MUST BE STARTED BY THE DAM) .. the problem is that I have to turn on the control of the indoor unit because otherwise it freezes ...
NG en linea
NG en linea
9.229
hace 6 años
hace 6 años
Hello, if I did not misunderstand when you turn on the remote, without putting the switch the 2 units start, when you turn off the outdoor unit stays on, so you have to turn off the switch If so, the reason is that the plate relay, which sends the current to the compressor stays stuck or closed, allowing current to pass through all the time.
Yadian Castañeda Cruz
hace 6 años

What happens is that the one who installed the split put a switch on the wall for when people go outside to turn it off ... it happens that to turn on the split you have to raise the switch but when I do it starts the outdoor unit .... without touching the knob ... it is as if the unit is direct and then it starts to throw cold gas for the indoor unit which is turned off ... quickly it must be turned on so that it does not freeze ... I don't have much experience in that but I am a little intrusive ... thanks for answering ... I wait for more response

Responder
NG en linea
NG en linea
9.229
hace 6 años

As I explained, the electronic card relay is stuck and current flows to the condenser. Change that relay

Responder
Yadian Castañeda Cruz
hace 6 años

OK thanks...

Responder
Yadian Castañeda Cruz
hace 6 años

Thanks ... that was what I was screwed. ...

Responder
orestico
hace 6 años
hace 6 años
relay locked .....
Yadian Castañeda Cruz
hace 6 años

OK thanks. .

Responder
friovega63
friovega63
11.849
hace 6 años
hace 6 años
Hi Yadian, what I understand from your writing, is that you are using the micro switch, auxiliary boot, to turn on the computer, and then it freezes, but by the remote control or remote control this does not happen. Obviously something like this happens, because the micro switch button, is used, only to start the equipment in emergent conditions, because for example, the remote control does not work, at the moment we decided to use the air conditioning, because said command, has The batteries are exhausted or the equipment does not simply respond to the order that, through it, we try to give to the equipment. The auxiliary start micro switch, as the name implies, is just for that I repeat and it activates a programming, which operates the compressor, at the maximum limit of its lowest or coldest temperature, so a stop would be conditioned , depending on how well or poorly heated the room or the room can be cooled or even at the time or season of the year in which it is located. However, it would be good to check the anti-frost, coil or well sensor, as you prefer to call it, because it should not allow the equipment to freeze, without stopping the compressor when censoring, the slightest formation of ice or frost on the evaporator. Luck. S @ lu2 friovega63.
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.84
(25)

Curso Práctico de Reparación y Bobinado de Motores Eléctricos

Héctor Castiñeira
$ 60 USD
$ 20 USD
4.6
(10)

Curso Localización de Fallas en Refrigeración en Heladeras/Neveras On/Off

Yamil Alarcón
$ 29 USD
$ 12 USD
4.71
(7)

Curso TV OLED y QLED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 29 USD
$ 10 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis