john yepez
hace 6 años
hace 6 años
Hello I would like to know if this theory of. Add 30 to r22. Or 80 to 410 of the room temperature is safe and it's so simple like this example for r22 If the room temperature is in 22 degree I just have to load it up to 52 pounds
CHIALVA JESUS ERNESTO
hace 6 años
hace 6 años
John, ideally, when you make a refrigerant charge, is to do it by weight, which the manufacturer recommends,
TRIATLON99
TRIATLON99
6.267
hace 6 años
hace 6 años
Hi, yes, it works, but you should take into account consumption and thermal jump as well, but it is quite successful to make that sum at room temperature. Regards
elektomaq
elektomaq
62.202
hace 6 años
hace 6 años
Hello It is a fairly effective guide and with an acceptable error range, although it has a lot to do with other conditions such as cleaning, fan speed, motor compressor status, insulation status, etc. regards
john yepez
hace 6 años

Moto compressor and insulation could explain it with a small example please

Responder
elektomaq
elektomaq
62.202
hace 6 años

If the motocompressor compresses less either for electrical or mechanical reasons, the pressure will be affected even if it is not for 4 or 5 psi, something that usually does not attract the attention of the person who performs the controls

Responder
elektomaq
elektomaq
62.202
hace 6 años

If the pipe insulation is degraded or non-existent, there will be a direct effect on the pressures as well as the performance

Responder
NG en linea
NG en linea
9.229
hace 6 años
hace 6 años
Hi. As you have explained in this forum, so dry that sum that is made of room temperature + 30 .... etc, is not a key,. Manufacturers and those who do quality control DO NOT take that factor into account There are three basic elements to measure equipment performance, and it must be done in the place to be heated There are 2 that were already mentioned: Thermal load and consumption However the most effective and that give a touch of greater precision are Overheating and subcooling.
john yepez
hace 6 años

Friend ng easily as I determine these Elmentos thermal load. Overheating sufriami ento

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.25
(8)

Reparación de Placa Main TV LED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 40 USD
$ 20 USD
4.64