adrian cabreradolores
hace 6 años
hace 6 años
Hello .. from Veracruz Mexico. It turns out they gave me a Carrier brand mini split, but with the cables cut to the raz. So that does not bring or plug. I have installed a few mini split family members, but new, have not had problems so far. The problem with this is that it does not bring the plug ... I would like someone to help me if it is possible to send me the manual, or just tell me what the connection sequence is like. In each team it brings a window with four connections like this ... 1234. It is Carrier model 38 HPC 091 CC .. of 9000 BTU. R-22 He is old but it works. Thank you
friovega63
friovega63
11.849
hace 6 años
hace 6 años
If you bring the directly installed power input cable, you should only match the numbers with each indoor and outdoor unit, 1 with 1 and so on. Generally on the cover of the record of each unit, it carries the electrical connection diagram, you can upload images of the connection strips, to help you better. If you also do not bring the power input cable from the phase outlet, you must separately take a neutral phase cable, to the neutral point of the electronic board and another phase, to power the common point of the compressor relay in the electronic card itself, all this would be separate repeat of connection 1 with 1, 2 with 2, and so on. Luck. S @ lu2 friovega63.
adrian cabreradolores
hace 6 años

Okay. Friovega63 ... The part of connecting 1 with 1, 2 with 2, etc ... if I understand it ... I kept the idea of the plug, now that you explain it the second time, I will look for it to do the tests .. while I'm at home ... But I also tell you that it does not bring the connection cover ... I mean there is no connection diagram ... Thank you I will notify you later

Responder
friovega63
friovega63
11.849
hace 6 años

Remember if you do not have the phase input power cable, you must add it separately to 1,2,3,4.

Responder
friovega63
friovega63
11.849
hace 6 años

According to the explanation already mentioned.

Responder
adrian cabreradolores
hace 6 años

It is very difficult to send an image, since after you select it, I could even take you to the photo measurements and a whole row.
But I tell you .. I already saw the condenser board .. it's like this ... LN 1 2 3 4, the evaporator board is 1 2 3 4 ... I think the plug or outlet is the L and N ... And the two teams connect with the sequence of 1 2 3 and 4.
Thanks for your help

Responder
friovega63
friovega63
11.849
hace 6 años

Likewise, as I have already told you, match the numbers and the plugs, light or general phase socket enters through the outdoor unit or condenser.

Responder
adrian cabreradolores
hace 6 años

Correct friovega63 ... I will follow your advice. I'll tell you how it looked after, I'm still going to give it maintenance, because it's fine pig ... Thanks

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.25
(8)

Reparación de Placa Main TV LED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 40 USD
$ 20 USD
4.87
(15)

Curso Diseño de Amplificadores de Máxima Fidelidad

Maximiliano Resch
$ 29 USD
$ 13 USD
4.94
(16)

Curso Refrigeración Comercial Aplicado a Diagnóstico y Reparación

Ing. Georga Melgarejo
$ 40 USD
$ 13 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis