⚡ Descuentos en cursos en video - Lleva tu aprendizaje técnico al siguiente nivel y aprovecha precios especiales antes de que termine la oferta. 🔥 Aprovechar oferta ahora 🔥
Air conditioner

I have an air conditioner that turns on the indoor unit

Flaco fabian
hace 6 años
hace 6 años
Hello good night, you know that I have an air that starts alone and is only the indoor unit. It is a 12000 BTU device which worked perfectly. They have some idea of what may be happening. Thank you
dobanon piero
hace 6 años
hace 6 años
good night that failure is common the relet of the main card is getting stuck you have to replace it to resume its proper operation
Flaco fabian
hace 6 años

Hi Piero, but if the relay turned on this would not make the outdoor unit work as it would energize the compressor or you say the fan relay. Because in the outdoor unit does not turn on anything.

Responder
friovega63
friovega63
11.849
hace 6 años
hace 6 años
Hi Skinny, depending on the model of your equipment, you may have to lift the front mat that covers the air filters, also on the display itself or through a hole to the far right on the equal front of the equipment to locate on that front of the indoor unit, the auxiliary ignition micro switch and tries to press it repeatedly with the equipment off and without power, such as turning it on and off constantly, then do it turning on and off, once again but already with the unit energized. Then turn on normally through the remote control and check if the problem happens again. If after following this procedure, the fault still remains, in that case you should change the auxiliary ignition micro switch, because these over time and due to the high relative humidity to which it is exposed, it becomes sulphated his internal contacts and for that reason he begins to make false contact inside, causing the fault he already knows. Comment please. Luck. S @ lu2. friovega63.
Flaco fabian
hace 6 años

Hi Friovega, we will try and see what happens and I will tell you again.

Responder
Flaco fabian
hace 6 años

Do what you told me and well this continued to make the problem of lighting alone and that's why I made the decision to buy an original new plate.

Responder
Debeku
Debeku
7
hace 6 años
hace 6 años
If the indoor unit of the Split turns on but the compressor does not start or the extractor fan may be a fault in the card that does not activate the relay or it may be the compressor's starting capacitor that has been damaged and must be replaced, it found in the external drive.
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.84
(25)

Curso Práctico de Reparación y Bobinado de Motores Eléctricos

Héctor Castiñeira
$ 60 USD
$ 20 USD
4.94
(16)

Curso Refrigeración Comercial Aplicado a Diagnóstico y Reparación

Ing. Georga Melgarejo
$ 40 USD
$ 13 USD
4.64
(45)

Curso Tecnología Inverter - Fabricación de probadores y herramientas

Yamil Alarcón
$ 240 USD
$ 40 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis